![Teldat Regesta PLC Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/teldat/regesta-plc/regesta-plc_installation-manual_1079544012.webp)
• Steady: Data is not being transferred.
• Flashing: Data is being transferred.
S2
Multi standard seri-
al interface 2
Off
Green
Serial port 2 is disabled or not initialized.
Port is in active state, shows interface activity:
• Steady: Data is not being transferred.
• Flashing: Data is being transferred.
Please note that some LEDs may behave differently depending on how the device is configured.
3.1.2 Connector panel
The connector panel is covered by a protective casing.To access the connection panel you need to remove the pro-
tection. For further information on how to remove/install the protective casing, please, see
on page 10.
The following figure shows the connector panel. This panel includes all Regesta PLC router connectors.
Fig. 3:
Connector Panel
The connector panel components are as follows:
Table 2: Connector panel components
Item
Description
A
RST. Reset button. For further information on how the reset button works, please see
on page 15.
B
CONF. RJ-45 connector providing access to the device's local console for configuration and
monitoring purposes. (This connector can also be used as an RS-232 asynchronous DCE
serial port.)
C
Fast Ethernet Port 1.
D
Fast Ethernet Port 2 (Optional). This port can support up to 10 KV of voltage isolation, de-
pending on model.
E
POWER/PLC. Power connection and PLC signal injection. For further information on the
power connection, please see
on page 14.
F
RS485,RS232. For more information on the connector for serial ports, 2-4 wire RS-
485/RS-422 and DCE RS-232, see
on page 18.
3 Components and Power Supply
Teldat S.A.
8