TELCOSAT RPT 900
Document use is restricted to that described on cover
10
2.3 AC POWER DISTRIBUTION
AC
input power via a power cord which feeds a power supply that converts the AC to DC low voltage.
The DC power provides all the necessary requirements for the active components.
The repeater is equipped with a red LED power on light.
Power Supply Specifications,
-40c° to +50c° Operating Temperature Range
Short circuit, over power and over voltage protection
Input Power, 100-240 VAC
47/63 Hertz
Output Power, 12VDC/5AMPS
Approvals, UL, CUL, CE
CHAPTER 3
INSTALLATION
READ THESE INSTRUCTIONS PRIOR TO INSTALLATION
3.1 WARNING
Cellular Repeaters should be installed by fully trained technicians. Improper installation and excessive
RF power levels can cause interference with the operation of cellular towers.
Antennas must be mounted in a secure safe manner and according to safe working practices.
To protect your equipment, lightning protection hardware is recommended when installing a cellular
repeater unit.
Antennas must not be installed near overhead electrical power lines as this can cause serious injury
and or death.