15
Installing the Equipment
2.4.2
Connecting to a VoIP Network
The TSBC3000 series features redundant GigE ports for connection to different VoIP networks. This
provides an access point to manage VoIP traffic. Should one of the IP physical interface go down, the
TSBC3000 series will continue to manage VoIP traffic using the alternate physical interface.
The IP address of the VoIP ports can be modified using the web portal.
Note:
Certain configurations of the TSBC3000 series will exceed 100 Mbps, therefore 1000
Mbps is recommended.
Prerequisites
To connect the TSBC3000 series to the VoIP network, you will need:
•
Gigabit layer 2 Ethernet switch. A second one is required to support redundancy of the VoIP
interface.
•
One or two CAT5 Ethernet cables with RJ45 male-male terminations.
Connections
The TSBC3000 series is connected to the VoIP network by one or optionally two Ethernet GigE network
links, as shown in
To connect the TSBC3000 series unit to the VoIP network:
1. Connect a CAT5 Ethernet cable to VoIP0 at the rear of the TSBC3000 series. Connect the other
end of the same CAT5 cable to the gigabit Ethernet switch.
2. If your system employs a second gigabit Ethernet switch for redundancy, connect a second CAT5
Ethernet cable to VoIP1 at the rear of the TSBC3000 series. Connect the other end of the same
CAT5 cable to the second gigabit Ethernet switch.
Figure
2.3
Connecting to the VoIP Network
Gi
g
abit Ethernet Switch 1
Vo
Network 2
IP
Vo
Network 1
IP
15
14
13
12
10 11
8
9
3
2
0
7
6
5
4
1
MGMT0
MGMT1
ETH0
ETH1
VOIP0
VOIP1
MGMT0
ETH
VOIP
0
1
0
1
TMS
0
1
Gi
g
abit Ethernet Switch 2
TSBC3000-680
TSBC3000-2700
Gi
g
abit Ethernet Switch 1
Vo
Network 2
IP
Vo
Network 1
IP
Gi
g
abit Ethernet Switch 2
Содержание TSBC3000
Страница 1: ...Installation Guide TSBC3000 Session Border Controller August 31 2016...
Страница 41: ...35 Installing the Equipment 3 Select a host from the Host Configuration List 4 Select the Status tab...
Страница 50: ...TSBC3000 Series Standalone and TSBC3000 Series 1 1 System Installation Guide 44...