www.tekvox.com
4K ePTZ Camera
79068-AT2 User Manual
Soap Port
: Set the Soap port (Default: 1936; 0 ~ 65535 optional)
RTMP Port:
Set the RTMP port (Default: 1935; 0 ~ 65535 optional)
RTSP Port
: Set the RTSP port (Default: 554; 0 ~ 65535 optional)
Visca Port
: Set the Visca port (Default: 1259; 0 ~ 65535 optional)
WebSocket port:
Set the WebSocket port (Default: 8088; 0 ~ 65535 optional)
Click the "Save" button to display the "Save Successful" message, then the new settings will take
effect (device will reboot automatically after settings are saved)
RTSP Obtaining Method
: rtsp: // [Camera IP Address] : 554 / live / [Stream, ID]
[Stream ID]
= “
av0
” for
Close-up Main Stream,
“
av1
” for
Close-up Sub-Stream,
“
av2
” for
Panoramic Main Stream,
“
av3
”
for Panoramic Sub-Stream,
and “
av4
”
for Broadcast Code
Stream)
RTMP Obtaining Method
: rtmp: // [Camera IP Address] : 1935 / live / [Stream ID]
[Stream ID]
= “av0” for Close
-
up Main Stream, “av1” for Close
-up Sub-
Stream, “av2” for
Panoramic Main Stream, “av3” for Panoramic Sub
-
Stream, and “av4” for Broadcast Cod
e
Stream)
5.4.3.2 Ethernet Parameters
DHCP:
Enable/disable whether to obtain an IP address automatically (Default: Off)
IP Address:
Set the static IP address (Default: 192.168.5.163)
Note
: This IP address is the same one used to log in to the Web GUI
Subnet Mask:
Set the subnet mask (Default: 255.255.255.0)
Default Gateway
: Set the default gateway (Default: 0.0.0.0)
MAC Address
: The
camera’s MAC
address is read-only and cannot be modified
Click the "Save" button to display the "Save Successful" message, then the new settings will take
effect (device will reboot automatically after settings are saved)
5.4.3.3 DNS parameters
Preferred DNS server
: Set the preferred DNS server (Default: 0.0.0.0)
Alternate DNS server
: Alternate DNS server settings (Default: 0.0.0.0)
Click the "Save" button to display the "Save Successful" message, then the new settings will take
effect
5.4.3.4 GB28181
Switch
: Select whether to use the GB28181 IP communication standard
Time Synchronization
: Select whether network time is synchronized
Stream Type
: Select stream type (Default: Main Stream; Secondary Stream optional)
Sign effective time (in seconds)
: Default: 3600; 5 ~ 65535 optional
Heartbeat time (seconds)
: Default: 60; 1 ~ 65535 optional
Register ID
: 34020000001320000001
Register User name
: IPC
Register Password
: 12345678
Equipment ownership
: Can be entered by user