General Maintenance
Table 4-4: Symptoms and causes (cont.)
Symptom
Possible sources or recommended detailed troubleshooting procedure to follow
Failures while running the advanced
diagnostics:
DSP1 QDR1 Memory 1
DSP1 QDR2 Memory 2
DSP2 QDR1 Memory 1
DSP2 QDR2 Memory 2
DSY DDR Buffer 1 Memory
DSY DDR Buffer 2 Memory
DSY DDR Trig Buffer Memory
DSY SDRAM Buffer 1 Memory
DSY SDRAM Buffer 2 Memory
Perform secondary power supply checks
Replace main board
Diagnostic Log Message:
Fail AUDIO_DSP_HEARTBEAT
Search for an intermittent problem in the audio board, cables, or main board.
No text or traces on display
Replace Main board
4–8
WVR8200 and WVR8300 Waveform Rasterizers Service Manual