![Tektronix WFM5200 & WVR5200 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/tektronix/wfm5200-and-wvr5200/wfm5200-and-wvr5200_how-to-manual_1078784021.webp)
How to Guide
Audio Loudness Monitoring
21
www.tektronix.com\wfm8000
www.tektronix.com\wfm7100
www.tektronix.com\wfm5200
Function
Description
EBU R/128 (+18 scale)
This preset loads a configuration in compliance with EBU R/128 and
configures the following settings:
Loudness Filter/ Measure - LKFS (BS.1770)
Momentary Integration Time - EBU R/128 (400ms)
Average Integration Time - 3 seconds
Channel Weighting - ITU-R BS.1770
Custom Mask - Press SEL
Target Loudness -23LUFS
Target Loudness High 1LU
Target Loudness Low 1LU
Gating Type - Relative
Safety Gating Level -70 LUFS
Relative Gate level -10LU
Loud A-D Conversion -18dBFS
IEC 61672
This preset loads a configuration in compliance with
IEC 61672 and
configures the following settings:
Loudness Filter/ Measure - Leq(A)
Momentary Integration Time - IEC 62672 (125ms)
Average Integration Time - 10 seconds
Channel Weighting - Custom
Custom Mask - Press SEL
Target Loudness -24dBFS
Target Loudness High 2dB
Target Loudness Low 2dB
Gating Type - Disabled
Safety Gating Level -99dBFS
Relative Gate level -0dB
Loud A-D Conversion -20dBFS
ARIB TR-B.32
This preset loads a configuration in compliance with ARIB TR-B.32 and
configures the following settings:
Loudness Filter/Measure - LKFS (BS.1770)
Momentary Integration Time - EBU R128 (400ms)
Average Integration Time - 3 seconds
Channel Weighting - Custom
Custom Mask - Press SEL
Target Loudness -24LKFS
Target Loudness High 1 LU
Target Loudness Low 1 LU
Gating Type - Relative
Safety Gating Level -70LKFS
Relative Gating Level -10LU
Loud A-D Conversion -18dBFS