at the interconnecting plug between pin 1 and
ground, and between pin 3 and ground. The
voltage should be between +65 and +70 volts
on each pin.
5. V a ria b le Attenuator Balance
Adjustment
With the AC-DC switch in DC position,
rotate the VARIABLE (VOLTS/CM) control
back and forth while watching the crt fo r a
shift in position of the trace. If the trace
moves when the control is rotated, adjust the
upper VARIABLE ATTEN. B A L. control on
the front panel until the trace position is no
longer affected by the V ARIABLE (VOLTS/CM)
control.
no longer affected by the VARIABLE (VOLTS/
CM) control.
Return VARIABLE control to
CALIBRATED position.
7. Check A C -D C Switch
Set the AC-DC switch at DC position. Apply
a 100 M IL L IV O L T square wave signal from
the AM PLITUDE CALIBRATO R to the INPUT
connector of the Type L Unit. Position the
base line of the calibrator waveform on the
center line of the graticule. Turn the AC-DC
switch to AC.
The waveform should shift
down centering the display on the graticule.
8. Cathode Current Adjustment
6. X10 V a ria b le Attenuator Balance
Adjustment
With the AC-DC switch at X10 GAIN AC
and the VARIABLE ATTE N .
B AL. control
calibrated, rotate the V ARIABLE (VOLTS/CM)
control back and forth while watching the crt
fo r a shift in position of the trace. If the
trace moves when the control is rotated, adjust
the X10 VARIABLE
ATTEN. B AL. control
on the front panel until the trace position is
It is very important that the voltages at
the elements of V6042 be within certain limits.
These voltages can be varied over a limited
range by adjusting the control grid voltage
o f the tube. With a tube in good condition, all
o f the element voltages w ill be within proper
operating lim its if the cathode current is .17
m illiam peres--indicated by a voltage drop of
55 volts across the precision 6-kilohm resistor,
R6072.
F ig. 5-1. Bottom view of L Unit showing location of Cathode Current test points and X10-amplifier
high-frequency coils.
L5942
L6012
Cathode Current Test Points
(R6072)
H. F. P eakin g
(R6692)
L5902
AA
Calibration Procedure - Type L Plug-In