HDLG7 HD Dual Link Video Generator
Table 3-35: HDLG7 module projector test pattern set assigned to the test signal
buttons (cont.)
Button name
Signal set
Signals in the signal set
FLAT FIELD
Flat Fields
Black Flat Field, White Flat Field,
Black to White Step-1, Black to White Step-2,
Black to White Step-3, Black to White Step-4,
Black to White Step-5, Black to White Step-6,
Black to White Step-7, Black to White Step-8,
Black to White Step-9, Black to White Step-10,
Black to Gray Step-1, Black to Gray Step-2,
Black to Gray Step-3, Black to Gray Step-4,
Black to Gray Step-5, Black to Gray Step-6,
Black to Gray Step-7, Black to Gray Step-8,
Black to Gray Step-9, Black to Gray Step-10
MULTI BURST
——
——
SWEEP
——
——
MONITOR
Monitor
Red-1 Field, Red-2 Field, Green-1 Field, Green-2 Field,
Blue-1 Field, Blue-2 Field, Cyan-1 Field, Cyan-2 Field,
Magenta-1 Field, Magenta-2 Field, Yellow-1 Field,
Yellow-2 Field, Grid, Checkerboard, Aspect Ratio
PULSE BAR
Pulse & Bar
Window
TIMING
——
——
SDI
SDI
Equalizer Test, PLL Test, SDI Matrix
OTHER
——
Use this button to select the converter mode of operation
and Embedded audio selection menu. (See page 3-195,
Setting the Gradient Starting Point.
When you select Horizontal Gradient or Vertical Gradient in the Linearity
projector test pattern set, use the up (
▲
) or down (
▼
) arrow button to set the
starting point of the gradient. The available values are as follows:
Horizontal Gradient:
16 to 1913 in 1 level steps.
Vertical Gradient:
16 to 2880 in 1 level steps (2048 x 1080 format);
16 to 2404 in 1 level steps (2048 x 1556 format).
Selecting the Converter
Mode
Select from the following converter modes when you want to convert the SMPTE
292M 4:2:2 serial digital signal applied to the HD SDI IN connector into a dual
link output format:
60, 59.94, or 50 Hz Progressive Formats.
The HDLG7 module converts the input
interlace signal (60i, 59.94i, or 50i) to a progressive signal by doubling the frame
rate. The input signal is copied to both Link A and Link B, but the payload
identi
fi
er is modi
fi
ed to indicate a dual-link signal. The results are a 4:2:2 YCbCr
10-bit signal at the faster progressive rate (60p, 59.94p, or 50p).
TG700 TV Signal Generator Platform User Manual
3–195
Содержание TG700
Страница 1: ...xx TG700 TV Signal Generator Platform ZZZ User Manual P071197003 071 1970 03...
Страница 2: ......
Страница 27: ...Getting Started...
Страница 28: ......
Страница 34: ...Getting Started Figure 1 1 Installing the rackmount hardware 1 6 TG700 TV Signal Generator Platform User Manual...
Страница 67: ...Operating Basics...
Страница 68: ......
Страница 111: ...Modules...
Страница 112: ......
Страница 337: ...Index...
Страница 338: ......