Troubleshooting
TDS 420A, TDS 430A & TDS 460A Service Manual
6- 77
Troubleshooting Equipment
Equipment listed in Tables 4--1, 5--3, 6--4, and 6--8 of this manual, or equivalent
equipment, may be useful while troubleshooting this oscilloscope. Construction
of and set-up of other troubleshooting equipment are also listed in this section.
Table 6- 8: Troubleshooting Test Equipment, Fixtures, and Supplies
Item Number and
Description
Minimum Requirements
Example
Purpose
1.
Console Port
Tektronix part number
174-2613-00
Tektronix part number
174--2613--00 (see Figure 6--30
on page 6--79)
Troubleshooting using the
Console Port
2.
Computer
IBM
R
PC compatible
Troubleshooting using the
Console Port
3.
Extension cable
Console port to computer
connection
Troubleshooting using the
Console Port
4.
Telecommunication
software
RS-232, 9600 baud
Cross Talk
R
Troubleshooting using the
Console Port
5.
Oscilloscope
200 MHz (for the TDS 420A) or
400 MHz (for the TDS 430A
and TDS 460A) digitizing oscil-
loscope
TEKTRONIX TDS 430A,
TDS 420A, or TDS 460A
General troubleshooting
The console port allows you to see detailed diagnostic messages when faults in
the oscilloscope prevent display of the normal diagnostics. Use this procedure to
set up the console port:
NOTE
. You may need a DB-9 to DB-25 adaptor, null modem adaptor, gender
changer adaptor, and an extension cable to connect the console port to your
personal computer (see Figure 6--30 on page 6--30). Using Table 6--9 as a guide
you can wire a cable to take the place of a DB9 to DB25 adaptor, null modem
adaptor, gender changer, and an extension cable.
1.
Equipment required:
Console port (Item 1), a personal computer or
terminal (Item 2), and telecommunication (terminal) software (Item 4) for
the personal computer. Your personal computer may also require a DB-9 to
DB-25 adaptor, null modem adaptor, gender changer adaptor, and an
extension cable to connect the console port to your personal computer (see
Figure 6--30 on page 6--79).
2.
Prerequisites:
Power off the oscilloscope.
Console Port Set Up
Содержание TDS 420A
Страница 16: ...Service Safety Summary xii TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 36: ...Nominal Traits 1 14 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 44: ...Warranted Characteristics 1 22 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 54: ...Installation 2 6 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 64: ...Operating Information 2 16 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 72: ...Performance Verification Procedures 4 4 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 160: ...Maintenance 6 8 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 226: ...Removal and Installation Procedures 6 74 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 243: ...Troubleshooting TDS 420A TDS 430A TDS 460A Service Manual 6 91 J2 Pin 1 Figure 6 42 A02 Display Connector J2 ...
Страница 260: ...Options and Accessories 7 6 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 262: ...Electrical Parts List 8 2 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 272: ...Diagrams 9 10 TDS 420A TDS 430A TDS 460A Service Manual ...
Страница 287: ...TDS 420A TDS 430A TDS 460A Service Manual 10 15 1 2 3 4 5 6 7 3 8 9 10 11 Figure 10 5 Cables and routing B080000 Up ...