Warranted Characteristics
Warranted Characteristics
Warranted characteristics describe guaranteed performance within tolerance limits or certain type-tested requirements. (See
Table 1.) Warranted characteristics that have checks in the
Performance Veri
fi
cation
section are marked with the
symbol.
Table 1: Warranted electrical characteristics
Speci
fi
cation
TDP3500
Differential signal range (DC coupled)
±2.0 V
(DC + peak AC)
Common-mode signal range (DC coupled)
+5 V to –4 V
(DC + peak AC)
Maximum non destructive input voltage
between signal and common of the same
channel
±15 V
(DC + peak AC)
DC attenuation accuracy
±2% of input
Bandwidth (probe only)
DC to
≥
3.5 GHz
Rise time, probe only
(10–90%, + 20 °C to + 30 °C)
≤
140 ps
Common-mode rejection ratio
>60 dB at DC
>55 dB at 1 MHz
>45 dB at 30 MHz
>25 dB at 1 GHz
Temperature
Operating: 0 to +40 °C (32 °F to +104 °F)
Nonoperating: –40 to +71 °C (–40 °F to –159 °F)
1
Humidity
Operating: 0-90% RH, tested at + 30 to +40 °C
Nonoperating: 0-90% RH, tested at +30 to +60 °C
1