8
SPG8000A User Manual
o
Once
:
In Once mode, the DST offset is applied only on
c
e on the date
and time
you
specify.
Set the DST
offset
to either
add
or
subtract
an
hour
from the time zone offset, depending on whether DST is starting
or
ending
in your location.
o
Recurring
:
In Recurring mode, the DST offset is applied when the
DST
START date and time that you specify occurs, and
it is removed
when the DST
END
date
and
time
that
you
specify
occurs. The
recurring
DST
offset can only be a positive number, such as one
hour.
The DST
START/END dates are formatted as the DST rules are written
(for example, DST starts on the First Sunday in March at 02:00). For
example, to
change
to daylight savings time, schedule the system to
add one hour to the time zone offset at 02:00:00 (local time) on March
6, 2011. To
return to standard time, schedule the system to remove the
DST offset at 02:00:00 on November 6, 2011. At the scheduled time
and date, the DST change
is
added to the time zone offset as seen from
the instrument display. You can then program the next scheduled DST
change.
An incoming VITC or LTC reference may have DST shift already applied. To
avoid duplicating DST shifts, disable the DST SCHEDULER if the time of day
reference has DST applied.
Task Scheduler
:
The task scheduler is responsible for triggering scheduled
events at the appropriate time. This includes DST changes and triggered alarm
outputs.
TC Offset*
:
Every time
code
output has an independent offset (hours,
minutes, seconds, frames) that can be added to the value of the selected time
code source.
TC Engine
:
The time
code engine runs at the rate specified through the user
interface and generates the actual time
code bit
s needed for each output.
LTC
: The instrument has four independent linear time
code outputs. Each output
can be set independently with regard to time
code format, module timing, and
time
code delay.
Analog Black
: The instrument provides three analog sync outputs. Each output
can be configured as NTSC or PAL Black burst (with optional VITC insertion)
or HD trilevel sync.
HD-SDI
:
Option SDI provides two independent HD
-
SDI test signal
generators, for which ancillary time
code (ATC) can be added.
Program Time
:
As an alternate to the local time of day, a program time counter
can be used as a time
code source for any output. This counter can represent
elapsed time, such as the time
code associated with program content during the
editing process, for example.
Reset Value
: The program time counter will start counting from the specified
reset value. Program time can be reset to this value at any time using either the
user interface or a general purpose interface (GPI) input.
Alarm Time
:
An alarm can be set to generate when the program time counter
matches a predefined value. For example, you can specify the start time
code
of your program content at 01:00:00:00. The program time can be initialized to
00:59:00:00 to start a one minute leader before the program. The alarm time
Содержание SPG8000A
Страница 53: ...SPG8000A User Manual 39 Figure 7 Removing a Power Supply module...
Страница 103: ...SPG8000A User Manual 89 Figure 22 SDI Overlay submenu...
Страница 182: ...168 SPG8000A User Manual Figure 61 AES button menu diagram...
Страница 190: ...176 SPG8000A User Manual Figure 73 EMBED button menu diagram...
Страница 194: ...180 SPG8000A User Manual Figure 77 DOLBY E CONFIG submenu diagram part 2...
Страница 197: ...SPG8000A User Manual 183 Figure 81 REF button menu diagram part 2...
Страница 200: ...186 SPG8000A User Manual Figure 84 SDI button menu diagram part 2...
Страница 211: ...SPG8000A User Manual 197 Figure 96 SDI ANC PAYLOAD submenu diagram part 2...
Страница 213: ...SPG8000A User Manual 199 Figure 97 STATUS button menu diagram part 1...
Страница 215: ...SPG8000A User Manual 201 Figure 99 SYSTEM button menu diagram part 1...
Страница 216: ...202 SPG8000A User Manual Figure 100 SYSTEM button menu diagram part 2...
Страница 222: ...208 SPG8000A User Manual PTP submenu Figure 104 shows the diagram for the PTP submenu Figure 104 PTP submenu...
Страница 223: ...SPG8000A User Manual 209 SNMP submenu Figure 105 shows the diagram for the SNMP submenu Figure 105 SNMP submenu diagram...
Страница 225: ...SPG8000A User Manual 211 Figure 107 SNMP TRAPS submenu diagram part 2...
Страница 226: ...212 SPG8000A User Manual GPI submenu Figure 108shows the diagram for the GPI submenu Figure 108 GPI submenu diagram...
Страница 240: ...226 SPG8000A User Manual Figure 123 PTP primary master menu diagram part 1...
Страница 241: ...SPG8000A User Manual 227 Figure 124 PTP primary master menu diagram part 2...
Страница 243: ...SPG8000A User Manual 229 Figure 126 PTP primary slave menu diagram part 2...