Getting Started
Operating Considerations
Electrical
The following table lists the electrical operating requirements for the RFM220
instrument. The complete electrical operating requirements are listed in the
RFM220 Speci
fi
cations and Performance Veri
fi
cation Technical Reference
.
Table 3: Electrical operating requirements
Requirement
Speci
fi
cation
Temperature, operating
+5 °C to +40 °C, 30 °C per hour maximum gradient,
temperature of the intake air at the front and sides of
the instrument
Altitude, operating
0 to 3,000 m (9,800 ft.)
Source voltage
100 to 240 V
AC
50/60 Hz,
fl
uctuations must not exceed
±10% of the nominal rate voltage
Power consumption
0.6 A, 100-240 V, 50/60 Hz, single phase
Peak inrush current
1 A peak at 240 V
AC
, 50 Hz
Fuse rating
Mains fuse is 2 A, 250 V, delay fuse; internal (not
operator replaceable). Refer servicing to quali
fi
ed
service personnel.
Overvoltage category
II (as de
fi
ned in IEC61010-1)
Pollution degree
2 (as de
fi
ned in IEC61010-1), rated for indoor use only
Software
For the best operating performance, Tektronix strongly recommends that
you install the RFM220 Aggregator and the RFM220 Client applications on
separate computers. The Microsoft .NET Framework 3.5 software needs to be
installed on the computer hosting the RFM220 Client.
Ethernet Network
The RFM220 instruments that will be monitored and the PCs running the
RFM220 Client application need to be connected to an Ethernet network which
has access to the PC or server running the RFM220 Aggregator application.
RFM220 User Manual
7
Содержание RFM220
Страница 1: ...xx RFM220 ISDB Tb Measurement Demodulator ZZZ User Manual P071289600 071 2896 00...
Страница 2: ......
Страница 10: ......
Страница 22: ...Compliance Information xii RFM220 User Manual...
Страница 26: ...Preface xvi RFM220 User Manual...
Страница 100: ...Operating Basics 74 RFM220 User Manual...