Operating Basics
18
PS2520, PS2520G, PS2521 & PS2521G User Manual
Master/Slave Operation
The SERIES and PARA controls on the front panel allow you to
internally connect Output 1 and Output 2 in series or parallel. When
you do this, Output 2 (the master output) sets Output 1 (the slave
output) to the same level as the Output 2 setting. These modes of
operation are also called series tracking and parallel tracking.
Output 3 is always independent. You can connect Output 3 in series
or parallel with the other outputs by using external connections only.
Table 1 shows the maximum output available for the power supplies
in SERIES and PARA operation
Table 1: Maximum Output in Series and Para Modes
Model
Series
Para
PS2520, PS2520G
40 V, 2.5 A
20 V, 5 A
PS2521, PS2521G
72 V, 1.5 A
36 V, 3 A
Series Tracking.
Select SERIES to internally connect Output 1 and
Output 2 in series. Output 2 is the master.
Press SHIFT
→
SERIES
The SERIES indicator lights.
Use the Output 2 settings to control the power to the load. The
Output 2 voltage setting should be one half of the total output
voltage desired. (The voltage across Output 1 and Output 2 in series
is twice that of Output 2.) The current setting for Output 2 controls
the maximum current available to the load. See Figure 12.
Содержание PS2520
Страница 1: ...User Manual PS2520 PS2520G PS2521 PS2521G Programmable Power Supplies 070 9196 01...
Страница 4: ......
Страница 14: ...Preface viii PS2520 PS2520G PS2521 PS2521G User Manual...
Страница 40: ...Operating Basics 26 PS2520 PS2520G PS2521 PS2521G User Manual...
Страница 50: ...Appendix B Maintenance 36 PS2520 PS2520G PS2521 PS2521G User Manual...
Страница 56: ...Index 42 PS2520 PS2520G PS2521 PS2521G User Manual...