Helpful Hints
Follow these helpful hints to make probing easier and noise free.
Low-inductance Grounding
Placing a ground plane on top of the IC package being probed can
minimize ground lead length and inductance. See Figure 8.
Figure 8: Low-inductance grounding
Attach a small piece of copper clad wire on top of the IC package
and connect it to the IC package ground connection. Use the
low-inductance ground pogo pin or the customizable ground lead to
keep the ground lead length as short as possible.