4.
Slide the front clamp against the braid as shown in the following figure. Make sure to fully seat the front
clamp onto the V clamp.
Figure 12: Add front clamp
5.
Install the gasket, clamp insulator, and inner clamp, as shown in the following figure.
Figure 13: Add gasket, clamp insulator, and inner clamp
6.
Flare the exposed inner shield cable braid back over the inner clamp as shown in the following figure. Make
sure you trim the excess braid so it does not protrude from the connector.