Preface

Terms

The following terms may be used in this document:

Clear.

This removes data on media/memory before reusing it in a secured

area. All reusable memory is cleared to deny access to previously stored
information by standard means of access.

Erase.

This is equivalent to clear.

Media storage/data export device.

Any of several devices that can be used

to store or export data from the instrument, such as a USB port.

Nonvolatile memory.

Data is retained when the instrument is powered off.

Power off.

Some instruments have a “Standby” mode, in which power is

still supplied to the instrument. For the purpose of clearing data, putting the
instrument in Standby mode does not qualify as powering off. For these
products, you will need to either press a rear-panel OFF switch or remove the
power source from the instrument.

Remove.

This is a physical means to clear the data by removing the memory

device from the instrument. Instructions are available in the product Service
Manual.

Sanitize.

This eradicates the data from media/memory so that the data cannot

be recovered by other means or technology. This is typically used when the
device will be moved (temporarily or permanently) from a secured area to a
non-secured area.

Scrub.

This is equivalent to sanitize.

User-modi

fi

able.

The user can write to the memory device during normal

instrument operation, using the instrument interface or remote control.

Volatile memory.

Data is lost when the instrument is powered off.

iv

DPO2000/B and MSO2000/B Series Declassi

fi

cation and Security Instructions

Содержание DPO2002B

Страница 1: ...DPO2000 B and MSO2000 B Series Oscilloscopes Declassification and Security ZZZ Instructions xx www tektronix com P077010801 077 0108 01...

Страница 2: ...ion in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc TekSecure...

Страница 3: ...vices 3 Built In Security Features 4 When to Use TekSecure 4 What TekSecure Does 4 Disable the LAN Port and Clear LAN Ethernet Settings 5 Disable the USB Device Port 6 Clear and Sanitize a Non Functio...

Страница 4: ...Table of Contents ii DPO2000 B and MSO2000 B Series Declassification and Security Instructions...

Страница 5: ...ile flash memory Instrument setups and reference waveforms may also be stored in flash memory or on USB drives connected to the instrument If you have any questions contact the Tektronix Technical Sup...

Страница 6: ...not qualify as powering off For these products you will need to either press a rear panel OFF switch or remove the power source from the instrument Remove This is a physical means to clear the data by...

Страница 7: ...333MHZ MT47H32M16CC 3 FBGA84 DDR memory contains the digital channel waveform acquisition data during operation Only by the processor system N A Acquisition board MSO2000 B Series only Remove power f...

Страница 8: ...destroy it Return the product to Tektronix and a new acquisition board will be installed and the instrument will be repaired and adjusted as necessary CMOS CLOCK SERIAL REAL TIME CLOCK CRYSTAL 7 X 8...

Страница 9: ...trument setups Yes Save USB host port on the front of the instrument Files can be deleted or overwritten on the instrument or a PC the USB flash drive can be removed and destroyed The USB host port ca...

Страница 10: ...locations to verify successful completion of waveform and setup erasure Displays a dialog indicating whether the secure erase was successful or unsuccessful NOTE TekSecure does not erase or change fac...

Страница 11: ...N port on the rear of the instrument 2 Push the front panel Utility button 3 Push the Utility Page lower bezel button and use the Multipurpose a knob to select I O 4 Push the Ethernet Network Settings...

Страница 12: ...relevant LAN Ethernet settings are also cleared Disable the USB Device Port To disable the USB device port follow these steps 1 Remove any USB cable or device from the USB device port on the rear of t...

Страница 13: ...will be installed and the instrument will be repaired and adjusted as necessary For removal instructions refer to the service manual part number 071 2331 XX available on the Tektronix Web site at www...

Отзывы: