Reference
28
Serial Mask Testing & Serial Pattern Trigger User Manual
Overview
Control elements and resources
Creating a new mask (cont.)
Align the mask
and the signal
7.
To align the signal with the mask, touch the Alignment
Autoset
button.
The signal is aligned with the mask. If you need to
minimize the number of mask hits on each acquisition,
touch
Autofit
.
This display assumes that the autoset undo preference
is off or that you touch Close to close the Autoset Undo
control window.
Select the
source
8.
In this example, we are using the default source, CH 1.
Change the
tolerance
9.
Set the Mask Margin Tolerance to the percentage of
margin used in the mask test (this example uses the
default OFF):
H
OFF
to test the signal to the selected mask
standard
H
Settings greater than 0% to expand the size of the
mask segments, making the test harder to pass
H
Settings less than 0% to reduce the size of the
mask segments, making the test easier to pass