Applications
Connect the Clock Recovery instrument to another Bit Error Rate Tester
(BERT)
Complete the following steps to connect the Clock Recovery instrument to another Bit Error Rate Tester. The actual
connections depend on your instrument.
Figure 9: Connecting the Clock Recovery instrument to another BERT instrument
1.
Connect the pattern generator data output connectors from the BERT instrument to the Clock Recovery Data Input
connectors.
2.
Connect the Error Detector data input connectors from the BERT instrument to the Clock Recovery Data Output
connectors.
3.
Connect the Clock Input connector from the BERT instrument to the Clock Recovery Clock Output connectors.