![Tektronix 2714 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/tektronix/2714/2714_programmers-manual_1077901027.webp)
Introduction to Programming
2714 & 2715 Programmer Manual
1–15
A printer, a plotter, or both can be added to your system to provide hard-copy
output. Printers are preferred for character-based data such as parameter values or
instrument settings. Plotters provide superior results when displaying graphical
data. A convenient approach is to install a printer on a parallel port of the
controller and a GPIB-compatible plotter on the bus. With this approach,
graphical data can be plotted directly from the spectrum analyzer when the
controller is not available.
See Setting the TALK ONLY Option on page 1–18.
Setting Up for GPIB Operation
Your equipment must be correctly configured before GPIB operations can be
performed. The following tasks must be completed:
H
Installation of cables between the system components
H
Configuration of the spectrum analyzer and device driver
H
Installation of the device driver into controller memory
H
Configuration of the (optional) printer and/or plotter
This section describes each task in detail.
If your system consists of a controller and spectrum analyzer, you can simply
connect one end of the interconnecting cable to each instrument. A star configu-
ration, daisy chain configuration, or combination of these (Figure 1–4) should be
used when more than two instruments are on the bus. Up to 15 instruments can
be connected.
To maintain electrical performance of the bus, use only one 2-meter cable per
instrument, and ensure that at least 2/3 of the connected instruments are
powered up.
Turn on the power to the spectrum analyzer. Press the key sequence:
[UTIL] [4] [0] [0]
A GPIB PORT CONFIGURATION Menu appears. It should resemble the one
shown in Figure 1–5. You will use this menu to configure the GPIB parameters.
Item 0 of the GPIB PORT CONFIGURATION Menu, STATUS, controls the
GPIB ONLINE/OFFLINE status (see Figure 1–5). After all preparations have
been completed and GPIB operations are ready to begin, press [0] on the
KEYPAD to toggle item 0 until the STATUS indicates ONLINE. The spectrum
analyzer is then ready to exchange information over the GPIB.
Printer or Plotter
(Optional)
Connecting the
Equipment
Configuring the Spectrum
Analyzer
Placing the 2714 or 2715
Online
Содержание 2714
Страница 4: ......
Страница 11: ...Introduction ...
Страница 12: ......
Страница 38: ...Introduction to Programming 1 26 2714 2715 Programmer Manual ...
Страница 39: ...Message Structure ...
Страница 40: ......
Страница 54: ...Instrument Specific Message Structure 2 14 2714 2715 Programmer Manual ...
Страница 55: ...Functional Groups ...
Страница 56: ......
Страница 85: ...Command Query ...
Страница 86: ......
Страница 179: ...Status Reporting ...
Страница 180: ......
Страница 197: ...Programming ...
Страница 198: ......
Страница 266: ...Programming 6 68 2714 2715 Programmer Manual ...
Страница 267: ...Appendices ...
Страница 268: ......
Страница 276: ...Appendix A RS 232 Concepts A 8 2714 2715 Programmer Manual ...
Страница 296: ...Appendix B GPIB System Concepts B 20 2714 2715 Programmer Manual ...
Страница 297: ...Index ...
Страница 298: ......
Страница 307: ......
Страница 308: ......