5. Set the function generator for a 1 -volt (peak-to
peak), 50-kilohertz sine-wave output.
6.
Connect the function generator output to the rear
panel
+X
INPUT connector via the 50-ohm termination
and 42-inch cable .
7. Center the display with the Horizontal Position
control, and position the trace on the center horizontal
graticule line.
8.
Check that the rear-panel TRACE ROTATION control
will align the trace with the center horizontal graticule
line.
D E FLECTI ON AN D Z-AX I S FUN CTI ON S
1 . Perform the Preliminary Set Up procedure.
2. Set the function generator for a 2-volt (peak-to
peak), 50-kilohertz sine-wave output.
3. Connect the function generator output to the rear
panel +X I N PUT connector via the 50-ohm termination
and 42-inch cable.
@
O perating I nstructions-60S
4. Center the display with the Horizontal Position
control and check that the X GAIN control will adjust
for
8
divisions of horizontal deflection.
5. Disconnect the signal from the +X INPUT connector
and apply it to the +Y INPUT connector.
6.
Center the display with the Vertical Position control
and check that the Y GAIN control will adjust for
8
divisions of vertical deflection.
7. Adjust the INTEN SITY control for a barely-visible
display.
8. Disconnect the signal from the +Y INPUT connector
and apply it to the +X I N PUT and +Z INPUT connectors
via the 50-ohm termination, 42-inch cable, BNC T
connector, and the 1 S-inch cable.
9. Notice that the right end of the crt display becomes
bright, and that the left end disappears.
1 0. Disconnect the function generator.
This completes the Functional Check procedure for the
608 Monitor.
2-5