![TEKTELIC Communications T0005982 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/tektelic-communications/t0005982/t0005982_user-manual_1077275009.webp)
LoRa Agriculture Sensor User Guide
T0005978_UG
Version # 1.9
TEKTELIC Communications Inc.
Confidential
Page 9 of 22
1.2
Physical Interfaces
Figure 3 below illustrates the customer accessible interfaces for the Agricultural Sensor. All
models share the same layout.
Legend:
1A = Input 2+ (RES)
1B = Input 1+ (RES)
2A = Input 2-
2B = Input 1-
3A = Input 3 (Thermistor 1)*
3B = Moisture 1 (Watermark 1)*
4A = Input 3 (Thermistor 1)*
4B = Moisture 1 (Watermark 1)*
5A = Input 4 (Thermistor 2)*
5B = Moisture 2 (Watermark 2)*
6A = Input 4 (Thermistor 2)*
6B = Moisture 2 (Watermark 2)*
7A = GND (RES)
7B = Power (RES)
RES = Reserved pins for Soil Surface Mount Module Only
*NOTE there is no polarity on either the Thermistors or Watermarks that are shipped in the kit
with the Elevated Pole Module. The wires can be installed into the terminal block pins either
way.
Figure 3 Agriculture Sensor Connector Block