2

 

Installation 

2.1

 

Included Product and Installation Material 

The following items are shipped with each sensor: 

 

LoRa IoT Agriculture Sensor with battery installed. 

 

A magnet to wake up the sensor from DEEP SLEEP.  

2.2

 

Safety Precautions 

The following safety precautions should be observed: 

 

The Agriculture Sensor is not a toy, KEEP AWAY FROM CHILDREN. 

 

Use only the specified Lithium Thionyl Chloride (LTC) cells. 

 

Do not exceed the maximum specified terminal voltages. 

 

All installation practices must be in accordance with the local and national electrical 
codes. 

 

Sensor inputs do not provide electrical isolation between each other. 

2.3

 

Unpacking and Inspection 

The following should be considered during the unpacking of a new Agriculture Sensor: 

 

Inspect the shipping carton and report any significant damage to TEKTELIC. 

 

Unpacking should be conducted in a clean and dry location. 

 

Do not discard the shipping box or inserts as they will be required if a unit is returned 
for repair or re-configuration. 

2.4

 

Equipment Required for Installation  

The following tools are required to install the Agriculture Sensor: 

 

Torx T10 screwdriver (8 x enclosure screws) 

 

Slotted screwdriver (internal terminal block connections) 

 

Wire Stripper 

 

Wire Cutter 

 

 

Содержание T0005982

Страница 1: ...ducts names and services are trademarks and registered trademarks of their respective companies TEKTELIC Communications Inc 7657 10th Street NE Calgary AB Canada T2E 8X2 Phone 403 338 6900 LORA IOT AGRICULTURE SENSOR User Guide Document Type User Guide Document Number T0005978_UG Document Version 1 9 Product Name Agriculture Sensor Product Code T0005982 Agriculture Sensor Soil Surface Mount Module...

Страница 2: ...ded note about using the sensor in direct sunlight Changed default configuration in Tables 3 4 as a result Added more detail about how soil moisture is measured between the two modules 1 3 May 14 2020 Release Mark Oevering Refined statement about direct sunlight in overview section Change to magnetic wake up pattern 1 4 May 27 2020 Release Zenon Herasymiuk Added battery polarity statement on Secti...

Страница 3: ... and Installation Material 12 2 2 Safety Precautions 12 2 3 Unpacking and Inspection 12 2 4 Equipment Required for Installation 12 2 5 Elevated Mount Sensor Mounting 13 2 6 Cable Installation 13 3 Power Up Commissioning and Monitoring 15 3 1 Reed Switch Awakening Procedure 15 3 2 Commissioning 17 4 Battery Replacement 18 5 Operation Alarms and Management 19 5 1 Configuration 19 5 2 Default Configu...

Страница 4: ... TEKTELIC Communications Inc Confidential Page 4 of 22 List of Tables Table 1 Agriculture LoRa IoT Sensor Models 6 Table 2 Agriculture Sensor Specifications 10 Table 3 Default Configuration Soil Surface Mount 19 Table 4 Default Configuration Elevated Mount 19 ...

Страница 5: ...lture Sensor Soil Surface Mount Model 7 Figure 2 Agriculture Sensor Elevated Mount Model 8 Figure 3 Agriculture Sensor Connector Block 9 Figure 4 Mounting Holes 13 Figure 5 Reed switch location 16 Figure 6 Agriculture Sensor magnetic reset wake up pattern 16 Figure 7 Agriculture Sensor magnetic UL triggering pattern 17 Figure 8 LED Location 20 ...

Страница 6: ...2 915 T0005983 AGRICULTURE SENSOR SOIL SURFACE MOUNT MODULE EU EU 863 870 MHz ISM Band 863 870 863 870 The main features of the Agricultural Sensor are the following Temperature Relative Humidity Sensor Reports temperature and relative humidity of the local environment PLEASE NOTE PLACING THE UNIT IN DIRECT SUNLIGHT WILL RESULT IN THE SENSOR REPORTING CASE TEMPERATURE AND RELATIVE HUMIDITY INSTEAD...

Страница 7: ...for 30 minutes in the morning and let dry until evening wet for 30 minutes let dry overnight wet again for 30 minutes the next morning and let dry until evening Soak over the next night and install WET This will improve the sensor response There are several things to note regarding installation depending on the use case for the Watermark sensor Please review Sensor Installation on Page 1 in the fi...

Страница 8: ...0005978_UG Version 1 9 TEKTELIC Communications Inc Confidential Page 8 of 22 Figure 2 illustrates the Agriculture Sensor Elevated Mount Model in the Enclosure a Exterior view b Inside view Figure 2 Agriculture Sensor Elevated Mount Model ...

Страница 9: ...ut 1 3A Input 3 Thermistor 1 3B Moisture 1 Watermark 1 4A Input 3 Thermistor 1 4B Moisture 1 Watermark 1 5A Input 4 Thermistor 2 5B Moisture 2 Watermark 2 6A Input 4 Thermistor 2 6B Moisture 2 Watermark 2 7A GND RES 7B Power RES RES Reserved pins for Soil Surface Mount Module Only NOTE there is no polarity on either the Thermistors or Watermarks that are shipped in the kit with the Elevated Pole M...

Страница 10: ...ight Soil Surface Mount Sensor 224g Elevated Mount Sensor 220g 233g with mounting plate Power Source Battery powered 1x C cell Lithium Thionyl Chloride LTC 3 6V NOTE If replacing the battery please ensure it is inserted with the correct polarity Network technology Frequency band LoRaWAN in multiple variants see Table 1 US 902 928 MHz EU 863 870 MHz Air Interface LoRa Battery Lifetime At least 10 y...

Страница 11: ...ature measurement range of 40 C to 125 C Ambient Light Range 0 01 to 65 535 lux Soil Moisture Input 11 1 33 1 37MHz Soil Temperature Input 22 0 5 1 5V Input 3 43 0 3 2 5V Watermark Input 5 6 4 80 8000 Hz From the manufacturer datasheet 1 Applicable to Soil Surface Mount only 2 Applicable to Soil Surface Mount only 3 Applicable to Elevated Pole only 4 Applicable to Elevated Pole only ...

Страница 12: ...tages All installation practices must be in accordance with the local and national electrical codes Sensor inputs do not provide electrical isolation between each other 2 3 Unpacking and Inspection The following should be considered during the unpacking of a new Agriculture Sensor Inspect the shipping carton and report any significant damage to TEKTELIC Unpacking should be conducted in a clean and...

Страница 13: ...ided for the modules cable gland and input cable 2 6 Cable Installation The Elevated Mount Sensor enclosure is provided with a waterproof cable gland through which all connections must be routed The supplied cable gland size is PG 7 This gland supports cables with a jacket outside diameter of 3 0 mm to 4 3 mm 0 118 to 0 169 The I O terminal blocks accept 30 16 AWG wire Select a cable that meets th...

Страница 14: ...2 See Figure 3 on Page 9 for input connections Signal connections should be connected to the positive terminal labeled Similarly the return path should be connected to the negative terminal labeled of the matching I O channel NOTE Elevated Mount Sensor I O are referenced to the sensor ground and are not isolated ...

Страница 15: ...odule comes out of the factory it is in the DEEP SLEEP mode 5 and can be activated using the specified magnetic pattern Also the same magnetic pattern can just be used to reset the Agriculture Sensor during normal operation getting it to try to rejoin the network The magnetic pattern in this application is hard coded not user configurable as illustrated in Figure 5 A magnet presence is achieved by...

Страница 16: ...ied to the Agriculture Sensor the Agriculture Sensor is reset and tries to join the network It may take about 10 sec from the Agriculture Sensor reset to seeing the LED activity showing join attempts Therefore as step 1 in the above is completed it takes about 13 seconds before observing the LED activity if step 2 is respected Figure 6 Agriculture Sensor magnetic reset wake up pattern 3 sec 3 sec ...

Страница 17: ... from the magnet sign at the top of the enclosure once all in less than 2 sec as shown in Figure 6 It is important to note here that mistakenly holding the magnet attached to the module for more than 3 sec may trigger a module reset as explained in item 1 Figure 7 Agriculture Sensor magnetic UL triggering pattern Note Replacing the batteries of the Agriculture Sensor does not cause the Agriculture...

Страница 18: ... top lid Replace the battery The Agriculture Sensor accepts C size 3 6 V LTC batteries The allowed replacement batteries are as follows o Xeno Energy part number XL 145F o Tadiran Battery part number TL 4920 S o Tadiran Battery part number TL 5920 S Once the Agriculture Sensor is powered and tries to join see Section 5 3 for LED behavior replace the cover and gasket Make sure that the gasket is pr...

Страница 19: ... the following Table 3 Default Configuration Soil Surface Mount Seconds per Core Tick 900 15 min Ticks per battery voltage measurement 96 24 hours Ticks per Ambient Temperature 1 15 min Ticks per Ambient Relative Humidity 1 15 min Ticks per Soil Moisture 1 15 min Ticks per Soil Temperature 1 15 min Ticks per Ambient Light 1 15 min The default configuration of the Elevated Mount Sensor for reportin...

Страница 20: ...e LoRa LED red blinks then one of the health checks has failed Consider replacing the battery or moving the sensor to an environment within the temperature range Immediately after the delay the join procedure will begin During the time the System LED will blink continuously until the sensor joins a network The LoRa LED will now blink whenever LoRa activity occurs on the sensor transmitting or rece...

Страница 21: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate th...

Страница 22: ...e subi même si le brouillage est susceptible d en compromettre le fonctionnement Cet appareil doit être installé et utilise à une distance minimale de 0 2 m du corps humain Proposition 65 WARNING This product can expose you to chemicals including lead nickel carbon black which is known to the State of California to cause cancer birth defects or other reproductive harm For more information go to ww...

Отзывы: