background image

TEKTELIC

 

C

OMMUNICATIONS 

I

NC

Document type: 

User Manual 

Document number: 

T0004906 

Document version: 

1.6 

Document Status: 

Approved 

Product name: 

Pearl Gateway 

Product codes: 

T0004437, T0004438, T0004372

 

 

 

 

 

 

TEKTELIC Communications Inc. 

7657 10

th

 Street NE 

Calgary, AB, Canada  T2E 8X2 

Phone: (403) 338-6900 

 

© 2017 TEKTELIC Communications Inc., All rights reserved. 
 
All products, names and services are trademarks and registered trademarks of their respective companies. 
 

Disclaimer: 

Material contained in this document is subject to change without notice. The material herein is solely for 
information purposes and does not represent a commitment by TEKTELIC or its representatives. TEKTELIC has 
prepared the information contained in this document solely for use by its employees, agents, and customers. 
Dissemination of this information and/or concepts to other parties is prohibited without the prior written consent 
of TEKTELIC. In no event will TEKTELIC be liable for any incidental or consequential damage in connection with the 
furnishing, performance or use of this material. 
 
TEKTELIC reserves the right to revise this publication in accordance with formal change control procedures defined 
by TEKTELIC. 

 

Содержание T0004372

Страница 1: ...ment is subject to change without notice The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives TEKTELIC has prepared the information contained in this document solely for use by its employees agents and customers Dissemination of this information and or concepts to other parties is prohibited without the prior written consent ...

Страница 2: ...g to antennas before Table 4 8 1 2 August 2 2017 Approved T Danshin Added MPE separation information for fixed gateway 1 1 July 31 2017 Approved T Danshin Clarifications for EMC filing antenna specifications 1 0 July 28 2017 Approved S Morrison Changed document number type and status for formal release as approved version 1 0 0 4 June 23 2017 Draft T Danshin Corrected FCC classification removed re...

Страница 3: ...Gateway Mounting 16 2 5 Pearl TTU Mounting 18 2 6 Ground Cable Installation 21 2 7 DC Power Cable Installation 24 2 8 RF Cable Installation 26 3 Radio Compliance Statements 27 4 Description du produit 29 4 1 Introduction 29 4 2 Overview 29 4 3 Interfaces Externes 31 4 4 Specifications 37 5 Installation 40 5 1 Précautions de sécurité 40 5 2 Déballage et inspection 41 5 3 Équipement requis pour l in...

Страница 4: ...Pearl Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 4 of 52 5 8 Installation du câble RF 51 6 Déclarations de conformité radio 52 ...

Страница 5: ...odulation is customer proprietary The Gateway is designed to be compliant with FCC Part 15 247 as either a frequency hopping spreads spectrum FHSS or Digital Transmission DTS System The module has a single transmitter capable of approximately 28 dBm maximum for the fixed gateway conducted at the TTU antenna port and about 20 dBm at the mobile gateway antenna port Table 1 1 lists the Pearl system h...

Страница 6: ...ial Page 6 of 52 Both Gateways contain a number of ports for data management including USB and Ethernet The Fixed Gateway also contains binary alarm inputs for site management Figure 1 illustrates Mobile Gateway while Figure 2 illustrates the Fixed Gateway Figure 1 Pearl Mobile Gateway ...

Страница 7: ...onnector Type Mating Connector ISM Antenna Port Front TNC jack Industry standard TNC plug GPS Antenna Port Front TNC jack Industry standard TNC plug USB A Front USB type A receptacle Industry standard USB type A plug USB B Front USB type B receptacle Industry standard USB type B plug DC Power Front 2 pin threaded circular plastic connector CPC Shenzhen Chogori Technology Co Ltd p n 33000111 02 or ...

Страница 8: ...ck SMA jack Industry standard SMA plug GPS Antenna Port Back SMA jack Industry standard SMA plug DC Power alarms Front Molex Mini fit 2x3 header Molex Mini fit 2x3 plug Site Alarms Front Molex Mini fit 2x4 header Molex Mini fit 2x4 plug USB A Front USB type A receptacle Industry standard USB type A plug USB B Front USB type B receptacle Industry standard USB type B plug Ethernet Front RJ 45 socket...

Страница 9: ...06 Version 1 6 TEKTELIC Communications Inc Confidential Page 9 of 52 Figure 4 Pearl Fixed Gateway Module Interconnect Site alarms USB B DC power alarms Ethernet USB A GPS antenna ISM antenna Chassis ground Front Bulkhead Rear Bulkhead ...

Страница 10: ...d illustrated in Figure 5 Table 1 4 Pearl TTU Module Interface Connectors Interface Location Connector Type Mating Connector ISM RF Antenna Port Top N type female Industry standard N type male Gateway module interface Port Bottom N type female Industry standard N type male Chassis Earth Ground Bottom Screw with lug Industry standard single hole lug for 8 32 screw ...

Страница 11: ...Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 11 of 52 Figure 5 Pearl TTU Module Interconnect Fixed Gateway Module interface Chassis ground IMS antenna port Top Bottom ...

Страница 12: ... 10V to 15V DC operating range 16V DC no damage 30W maximum Maximum 20A input overcurrent protection ISM antenna output power 5V DC 300mA maximum GPS antenna output power 5V DC 50mA maximum Weather Tightness Indoor product Regulatory Compliance CSA UL 60950 1 FCC Pt 15 Class B The Pearl Fixed Gateway Module specifications are listed in Table 1 6 Table 1 6 Pearl Fixed Gateway Module Specifications ...

Страница 13: ...lass B The Pearl TTU Module specifications are listed in Table 1 7 Table 1 7 Pearl TTU Module Specifications Attribute Specification Dimensions 222 2mm 8 7 wide x 101mm 4 0 deep x 287 3mm 11 3 tall Weight 2 1 kg 4 6 lbs Operating Temperature 40 C to 65 C 40 F to 149 F at sea level Including solar loading Relative Humidity 10 to 100 Operating Altitude Maximum 3 048 m 10 000 ft Surge protection 20kV...

Страница 14: ...ving a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device The specified ISM antennas are listed in Table 1 8 Antenna types not included in Table 1 8 having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Table 1 8 ISM Antennas Gateway Type IC Number Antenna Vendor Model Number Gai...

Страница 15: ...s is always required Ensure the Pearl Gateway Protective Earth Ground connection is properly terminated prior to the connection of any other interfaces The Pearl Gateway TTU contains primary lightning surge suppression on the RF ports The primary lightning protectors have the ability to shunt lightning energy to earth ground which includes the chassis Ensure that the Protective Earth Ground connec...

Страница 16: ...torque wrench 2 Anti oxidant compound NO OX ID Penetrox Noalox Ox Gard or equivalent 3 A small wire brush or emery cloth 4 A clean cloth 5 Weatherproofing tape kit for the RF connectors Scotch Wireless Weatherproofing Kit WK 101 recommended 6 Four M4 screws with locking hardware for Gateway mounting length according to application see next section 7 Four M8 screws with locking hardware for TTU mou...

Страница 17: ... M4 mounting screws shall tread into the gateway chassis by at least 5 mm but not more than 10 mm The Gateway Module mounting orientation is to be such that the chassis fins are vertical Ensure that the surface and related structure to which the Module is being mounted is secure and able to support a dead load of at least 136 kg 300 lbs Ensure sufficient free space around the bulkhead connectors f...

Страница 18: ...l bracket and one antenna bracket as illustrated in Figure 10 Each bracket shall be attached to the TTU module using four of the supplied M5 x 0 8 10mm stainless steel screws at the locations illustrated in Figure 8 Once the brackets are attached to the TTU module the module may be mounted To mount the TTU with bracket to a flat surface four site supplied stainless steel M8 bolts are required two ...

Страница 19: ...rap slots as indicated in Figure 8 and Figure 9 The TTU mounting orientation is to be vertical with the vent plug pointing down to earth Ensure that the surface or pole and related structure to which the Module is being mounted are secure and able to support a dead load of at least 136 kg 300 lbs Ensure sufficient free space around the bulkhead connectors for access and cable ingress Figure 8 TTU ...

Страница 20: ...arl Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 20 of 52 Figure 9 TTU Module Mounting with Small Brackets Slot for pole strap 4 places M8 screw or bolt 4 places ...

Страница 21: ... for each module The Protective Earth Ground connection is made through a 8 32 screw using an industry standard single hole lug as illustrated in Figure 6 for the Mobile Gateway Module Figure 6 for the Fixed Gateway Module and Figure 6 for the TTU Module The recommended ground cable gauge is 10 AWG minimum The Pearl Gateway grounding system shall follow local and national electrical codes The Prot...

Страница 22: ...tallation steps are as follows 1 Lightly abrade the surface of the chassis grounding area the paint free area around the ground screw hole with a fine wire brush or emery cloth to remove the oxide layer which may have formed 2 Use a clean cloth to remove any debris from this surface 3 Immediately coat the contact surface with a thin layer of anti oxidant compound 4 Install the ground cable with it...

Страница 23: ...Pearl Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 23 of 52 Figure 12 Pearl Fixed Gateway Module Ground Point 8 32 ...

Страница 24: ... external to the Pearl Gateway usually at the power source by convention An input overcurrent protection device rated not more than 20 A and with the appropriate current interrupt capacity for the power source must be incorporated into the non earthed conductor s of the DC supply DC power is supplied to the Mobile Gateway Module through a two pin circular plastic connector CPC The mating CPC conne...

Страница 25: ...to the Fixed Gateway Module through two pins of a six pin Molex Mini fit connector The mating connector shall be as specified in Table 1 3 and shall follow the signal assignment identified in Figure 15 Figure 15 Fixed Gateway Module DC Power Connector Signals Black DC Negative White DC Positive Keyed DC Power Connector CPC DC Positive DC Negative DC Positive Pin 5 DC Negative Pin 6 ...

Страница 26: ... equipment specification For the case of the fixed gateway transmit power configuration is not a function of antenna type The system maximum transmit power is configured assuming an antenna with the highest specified gain 8dBi is used If the 6dBi antenna is used the radiated power is 2dB less The RF connector interface to a cable is not generally water proof and must be taped to be used outdoors T...

Страница 27: ...ment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice applicable to the Pearl Fixed Gateway only Maximum antenna gain is 8 dBi and omnidirectional type Antenna with maximum gain used for this transmitter must be installed to provide a separation distance of ...

Страница 28: ...t must be installed by trained RF technicians Notice applicable to the Pearl Fixed Gateway only Maximum antenna gain is 8 dBi and omnidirectional type Antenna with maximum gain used for this transmitter must be installed to provide a separation distance of at least 0 33 m from all persons This product must be installed by trained RF technicians The IC label shall be visible from the outside of the...

Страница 29: ...pplication Internet of Things IoT https www lora alliance org La modulation FSK est propriétaire du client La passerelle est conçue pour être conforme à la partie 15 247 de la FCC comme système de spectre de propagation de fréquence FHSS ou de transmission numérique DTS Le module dispose d un seul émetteur capable d atteindre approximativement 28 dBm maximum pour la passerelle fixe conduit au port...

Страница 30: ...protégée contre les conditions de surcharge et les conditions de court circuit avec un circuit de protection auto réinitialisation interne Les deux passerelles contiennent un certain nombre de ports pour la gestion des données y compris l USB et Ethernet La passerelle fixe contient également des entrées d alarme binaires pour la gestion du site La figure 1 illustre la passerelle mobile tandis que ...

Страница 31: ...re 3 Table 4 2 Connecteurs d interface du module de passerelle mobile Pearl Interface Emplace ment Type de connecteur Connecteur compatible ISM Antenna Port De face TNC jack Fiche TNC standard de l industrie GPS Antenna Port De face TNC jack Fiche TNC standard de l industrie USB A De face Récepteur USB type A Connecteur standard USB type A de l industrie USB B De face Récepteur USB type B Connecte...

Страница 32: ...necteurs d interface du module de passerelle fixe sont listés dans le tableau 3 et illustrés à la figure 4 Table 4 3 Connecteurs d interface de module de passerelle fixe Pearl Interface Emplace ment Type de connecteur Connecteur compatible TTU interface Port arrière SMA jack Fiche SMA standard de l industrie GPS Antenna Port arrière SMA jack Fiche SMA standard de l industrie DC Power alarms De fac...

Страница 33: ... USB A De face Récepteur USB type A Connecteur standard USB type A de l industrie USB B De face Récepteur USB type B Connecteur standard USB type B de l industrie Ethernet De face RJ 45 socket Fiche technique standard RJ 45 Châssis Terre De face Visser avec patte Patte standard unique pour la vis 8 32 ...

Страница 34: ...T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 34 of 52 Figure 19 Pearl Fixed Gateway Module Interconnect Site alarms USB B DC power alarms Ethernet USB A GPS antenna ISM antenna Châssis Terre de face arrière ...

Страница 35: ...au 4 et illustrés à la figure 5 Table 4 4 Pearl TTU Module Interface Connectors Interface Emplace ment Type de connecteur Connecteur compatible ISM RF Antenna Port haut SMA jack Fiche SMA standard de l industrie Gateway module interface Port bas SMA jack Fiche SMA standard de l industrie Chassis Earth Ground bas Visser avec patte Patte standard unique pour la vis 8 32 ...

Страница 36: ... Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 36 of 52 Figure 20 Pearl TTU Module Interconnect Fixed Gateway Module interface Châssis Terre IMS antenna port haut bas ...

Страница 37: ...0 m 6 560 ft DC Power Input 12V DC nominal 10V to 15V DC operating range 16V DC no damage 30W maximum Maximum 20A input overcurrent protection ISM antenna output power 5V DC 300mA maximum GPS antenna output power 5V DC 50mA maximum Weather Tightness Produit intérieur Regulatory Compliance CSA UL 60950 1 FCC Pt 15 Class B The Pearl Fixed Gateway Module specifications are listed in Table 1 6 Table 4...

Страница 38: ... 1 FCC Pt 15 Class B Les spécifications du module Pearl TTU sont listées dans le tableau 7 Table 4 7 Pearl TTU Module Specifications Attribute Specification Dimensions 222 2mm 8 7 wide x 101mm 4 0 deep x 287 3mm 11 3 tall Poids 2 1 kg 4 6 lbs Température d utilisation 40 C to 65 C 40 F to 149 F Niveau ambiant au niveau de la mer y compris le chargement solaire Humidité relative 10 to 100 Altitude ...

Страница 39: ...sible indiqué Les types d antenne non inclus dans cette liste ayant un gain supérieur au gain maximal indiqué pour ce type sont strictement interdits pour être utilisés avec cet appareil Les antennes ISM spécifiées sont listées dans le tableauTable 4 8 Table 4 8 Antennes ISM Type de passerel le IC Nombre Fournisseur d antenne numéro de modèle Gain dBi Passerel le mobile IC 22504 T0004437 PCTel BMU...

Страница 40: ...onnecté en permanence La connexion terrestre de terre de protection au châssis est toujours nécessaire Assurez vous que la connexion de terre de protection Pearl Gateway est correctement terminée avant la connexion de toute autre interface Le Pearl Gateway TTU contient une suppression de surtension primaire sur les ports RF Les protecteurs de l éclairement primaire ont la possibilité de dériver l ...

Страница 41: ... outils suivants sont nécessaires pour installer le système Pearl Gateway 1 Une prise impériale et métrique avec jeu Torx et une clé dynamométrique 2 Composé anti oxydant NO OX ID Penetrox Noalox Ox Gard ou équivalent 3 Une petite brosse métallique ou un émeri 4 Un chiffon propre 5 Kit de ruban étanche aux intempéries pour les connecteurs RF Scotch Wireless Weatherproofing Kit WK 101 recommandé 6 ...

Страница 42: ...el de verrouillage et les épaisseurs de surface de montage les vis de montage M4 doivent marcher dans le châssis de la passerelle d au moins 5 mm mais pas plus de 10 mm L orientation de montage du module Gateway doit être telle que les ailettes du châssis sont verticales Assurez vous que la surface et la structure connexe à laquelle le module est monté sont sécurisées et capables de supporter une ...

Страница 43: ...tenne comme illustré à la Figure 10 Chaque support doit être fixé au module TTU à l aide de quatre des M5 x 0 8 10mm fournis Des vis en acier inoxydable aux emplacements illustrés à la figure 8 Une fois les supports attachés au module TTU le module peut être monté Pour monter le TTU avec le support sur une surface plane quatre boulons M8 en acier inoxydable fournis par le site sont nécessaires deu...

Страница 44: ...e comme indiqué sur la figure 8 et la figure 9 L orientation de montage TTU doit être verticale avec le bouchon d évent qui pointe vers la terre Assurez vous que la surface ou le pôle et la structure connexe à laquelle le module est monté sont sécurisés et capables de supporter une charge morte d au moins 136 kg 300 lbs Assurez vous un espace libre suffisant autour des connecteurs de cloisons pour...

Страница 45: ... Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 45 of 52 Figure 24 Montage du module TTU avec de petits supports Slot for pole strap 4 places M8 screw or bolt 4 places ...

Страница 46: ...ue module La connexion Terre protectrice est réalisée à l aide d une vis n 8 32 à l aide d une patte unique à l intérieur de l industrie comme illustré à la figure 6 pour le module de la passerelle mobile la figure 6 pour le module de la passerelle fixe et la figure 6 pour le module TTU La jauge de câble de terre recommandée est le minimum de 10 AWG Le système de mise à la terre Pearl Gateway doit...

Страница 47: ...e au sol sont les suivantes Débarrassez légèrement la surface de la zone de mise à la terre du châssis la zone libre de peinture autour du trou de la vis de terre avec une brosse métallique fine ou un émeri pour éliminer la couche d oxyde qui peut s être formée Utilisez un chiffon propre pour éliminer les débris de cette surface Enduire immédiatement la surface de contact avec une fine couche de c...

Страница 48: ...Pearl Gateway User Manual T0004906 Version 1 6 TEKTELIC Communications Inc Confidential Page 48 of 52 Figure 27 Pearl Fixed Gateway Module Ground Point 8 32 ...

Страница 49: ...habituellement à la source d alimentation par convention Un dispositif de protection contre les surtensions d entrée d au plus 20 A et avec la capacité d interruption de courant appropriée pour la source d alimentation doit être incorporé dans le s conducteur s non connecté s de l alimentation CC L alimentation en courant continu est fournie au module de passerelle mobile via un connecteur en plas...

Страница 50: ... au module de la passerelle fixe à travers deux broches d un connecteur Molex à six broches Le connecteur d accouplement doit être conforme au tableau 3 et doit suivre l assignation de signal identifiée à la figure 15 Figure 30 Module de connexion fixe Signaux du connecteur d alimentation CC Black DC négatif White DC Positive Keyed DC Power Connector CPC DC Positive DC négatif DC Positive Pin 5 DC...

Страница 51: ...de la passerelle fixe la configuration de la puissance d émission n est pas fonction du type d antenne La puissance d émission maximale du système est configurée en supposant qu une antenne avec le gain spécifié le plus élevé 8dBi est utilisée Si l antenne 6dBi est utilisée la puissance rayonnée est inférieure de 2dB L interface du connecteur RF sur un câble n est généralement pas étanche et doit ...

Страница 52: ...avec cet appareil L impédance d antenne requise est de 50 ohms Seule une antenne avec un gain maximal de 5dBi peut être utilisée pour la passerelle mobile testée Seule une antenne avec un gain maximal de 8dBi peut être utilisée pour la passerelle fixe Avis applicable uniquement à la passerelle mobile Pearl L antenne spécifié pour cet émetteur doit être installée à une distance de séparation d au m...