background image

Kona Macro User Guide 

T0004279_UG 

 

                        Version 1.1 

TEKTELIC Communications Inc. 

Confidential 

Page 2 of 34 

 

 

Revision History

 

Version 

Date 

Status 

Editor 

Comments 

1.0 

Oct 5, 2016 

Draft 

T. Danshin  First release 

2.0 

Nov 1, 2016 

Draft 

P. Chu 

Updated for 1TX-1RX Module Type, v2.1 Semtech 

SW 

2.1 

Nov 8, 2016 

Draft 

P.Chu 

Updated environmental and DC voltage specs 

2.2 

Dec 9, 2012 

Draft 

P. Chu 

Updated Commissioning Section to use GUI for 

Gateway operation 

2.3 

Jan. 23, 2017 

Draft 

S. Morrison  Renamed to User Guide, numerous updates 

2.4 

Feb. 09, 2017  Obsolete  S. Morrison  Updates to connector & mounting information 

2.5 

Mar. 07, 2017  Obsolete  S. Morrison  Changed ground lug to imperial 

2.6 

Mar. 08, 2017  Obsolete  S. Morrison  Added 10A maximum DC input rating 

2.7 

Mar. 08, 2017  Approved  S. Morrison  Added language translation & LoRa antenna type 

2.8 

Mar. 24, 2017  Approved  T. Danshin  Added MPE information 

 

Содержание T0004142

Страница 1: ...ined in this document is subject to change without notice The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives TEKTELIC has prepared the information contained in this document solely for use by its employees agents and customers Dissemination of this information and or concepts to other parties is prohibited without the prior...

Страница 2: ... voltage specs 2 2 Dec 9 2012 Draft P Chu Updated Commissioning Section to use GUI for Gateway operation 2 3 Jan 23 2017 Draft S Morrison Renamed to User Guide numerous updates 2 4 Feb 09 2017 Obsolete S Morrison Updates to connector mounting information 2 5 Mar 07 2017 Obsolete S Morrison Changed ground lug to imperial 2 6 Mar 08 2017 Obsolete S Morrison Added 10A maximum DC input rating 2 7 Mar ...

Страница 3: ...lation 14 2 6 Direct DC Power Cable Installation 15 2 7 RF Cable Installation 16 2 8 Copper Ethernet Cable Installation 16 3 Commissioning and Monitoring 17 3 1 Required Equipment 17 3 2 Procedure 17 4 Radio Compliance Statements 18 5 Description du produit 20 5 1 Vue d ensemble 20 5 2 Connecteurs 22 5 3 Caractéristiques 25 6 Installation 26 6 1 Précautions de sécurité 26 6 2 Déballage et inspecti...

Страница 4: ...ELIC Communications Inc Confidential Page 4 of 34 6 7 Installation du câble RF 31 6 8 Installation du câble Ethernet en cuivre 31 7 Mise en service et surveillance 33 7 1 Équipement requis 33 7 2 Procédure 33 8 Déclarations de conformité à la radio 34 ...

Страница 5: ...nd 3G 4G wireless Table 1 presents the currently available Kona Macro Gateway models Table 1 Kona Macro Gateway Models Model Product Code Description GPS Ant Direct DC Power Optical Copper Eth 3G 4G Ant LoRa Ant 1 T0004142 KONA MACRO 1 0 0 1 0 1 2 T0004470 KONA MACRO DC POWER 3G 4G 1 1 0 1 1 1 3 T0004250 KONA MACRO DC POWER 2X LORA 3G 4G 1 1 0 1 1 2 4 T0004251 KONA MACRO OPTICAL DC POWER 1 1 1 1 0...

Страница 6: ...Kona Macro User Guide T0004279_UG Version 1 1 TEKTELIC Communications Inc Confidential Page 6 of 34 Figure 1 Kona Macro Gateway Common Dimensions ...

Страница 7: ... Bulkhead Layouts 1 2 Connectors The Kona Gateway connector field is detailed in Figure 3 for the T0004250 model Not all connectors are present on other models The DC power connector is replaced by a hybrid DC power Fiber connector on models which support fiber backhaul capability as with the T0004252 model detailed in Figure 4 ...

Страница 8: ...KTELIC Communications Inc Confidential Page 8 of 34 Figure 3 Kona Macro Gateway T0004250 Connector Field GPS Antenna DC Power 2 pin CPC LoRa RF Antenna 1 LoRa RF Antenna 0 Enclosure Vent Protective Earth Ground LED Copper Ethernet 3G 4G Modem Antenna ...

Страница 9: ...nd their mating connectors are listed in Table 2 Table 2 Kona Macro Gateway Interface Connector Types Interface QTY Connector Type Mating Connector LoRa Antenna Ports 1 or 2 N Type female Industry standard N Type male 3G 4G Modem Backhaul Antenna Port 0 or 1 N Type female Industry standard N Type male Copper Ethernet Port 1 Threaded circular RJ 45 Shenzhen Chogori Technology Co Ltd approved mating...

Страница 10: ...loading Relative Humidity 10 to 100 Operating Altitude 60 m to 4 000 m 197 ft to 13 123 ft Power Input Direct DC 48 VDC nominal 37 to 57 VDC operating range after 42 V maximum start up threshold Positive or negative ground referenced feed SELV source required Maximum 10A input overcurrent protection Power Input PoE 802 3 at Type 2 Class 4 Mode A or Mode B standard but constrained to 3m maximum cab...

Страница 11: ...ays required Ensure the Kona Macro Gateway Protective Earth Ground connection is properly terminated prior to the connection of any other interfaces The Kona Macro Gateway contains primary lightning surge suppression on the Direct DC power port the Copper Ethernet port the GPS antenna port and the LoRa RF antenna ports The primary lightning protectors have the ability to bridge the interface isola...

Страница 12: ...3 Do not discard the shipping box or foam inserts as they will be required if a unit is returned for repair or re configuration 2 3 Required Equipment for Installation The following tools are required to install the Kona Macro Gateway module 1 A 6 point metric socket set and torque wrench drive 2 Anti oxidant compound NO OX ID Penetrox Noalox Ox Gard or equivalent 3 A small wire brush 4 A clean cl...

Страница 13: ...re is as follows 1 Bolt the wall mounting bracket to the Gateway module using the supplied bolts and washers 2 Install 2 site supplied M8 bolts into the wall at 139 7 mm 5 5 center spacing leaving the bold heads protruding with a 2mm gap from the wall surface 3 Hang the Kona Macro Gateway with bracket from the two bolts by inserting the keyhole slots at the top of the bracket onto the 2 bolts and ...

Страница 14: ...g system shall follow local and national electrical codes The Protective Earth Ground conductor terminated at the double hole lug point is mandatory and must be the first connection made to the Kona Macro Gateway during installation Proper routing and termination of this cable is key to robust lightning withstand performance in high susceptibility installations every effort shall be made to minimi...

Страница 15: ... the power source by convention The DC power cable shall be rated for outdoor application according to local and national electrical codes The CPC direct DC connector shall be as specified in Table 2 and shall follow the signal polarity identified in Figure 7 Figure 7 Direct DC Power CPC Connector Connection Polarity The hybrid direct DC power connector shall be as specified in Table 2 and shall f...

Страница 16: ... supplier of this tape system Note that the 3G 4G modem antenna port is not surge protected and accordingly the antenna must be located with the Gateway module or if remotely located an external surge suppressor must be provisioned 2 8 Copper Ethernet Cable Installation The Kona Macro Gateway Ethernet port may be used on a temporary basis for commissioning and maintenance or may be permanently con...

Страница 17: ...le between the Host PC and the bulkhead copper Ethernet connector RJ45 For a PoE powered installation a PoE power injector may be required 2 Apply DC power to the Kona Macro Gateway The initial current draw is expected to be greater than 0 1A If there is no current the polarity of the DC power cable connection may be reversed or the power source may not be configured properly 3 The Kona Macro Gate...

Страница 18: ...an experienced radio TV technician for help To comply with FCC IC RF exposure limits for general population uncontrolled exposure the antennas used for this transmitter must be installed to provide a separation distance of at least 80 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter Industry Canada This Device complies with Industry C...

Страница 19: ...34 Technology Band Frequency MHz Maximum Antenna Gain dBi LTE 2 1850 1910 3 0 4 1710 1755 6 0 5 824 849 3 0 13 777 787 6 0 17 704 716 6 0 25 1850 1915 3 0 UMTS 2 1850 1910 3 0 4 1710 1755 6 0 5 824 849 3 0 GSM 850 824 849 3 0 1900 1850 1910 3 0 CDMA BC0 824 849 3 0 BC1 1850 1910 3 0 BC10 817 824 3 0 ...

Страница 20: ...hernet optique et 3G 4G sans fil Le tableau présente les modèles Kona Macro Gateway actuellement disponibles Kona Macro Gateway Maquette Maque tte Product Code Description GPS Ant Direct DC Power Optical Copper Eth 3G 4G Ant LoRa Ant 1 T0004142 KONA MACRO 1 0 0 1 0 1 2 T0004470 KONA MACRO DC POWER 3G 4G 1 1 0 1 1 1 3 T0004250 KONA MACRO DC POWER 2X LORA 3G 4G 1 1 0 1 1 2 4 T0004251 KONA MACRO OPTI...

Страница 21: ...Kona Macro User Guide T0004279_UG Version 1 1 TEKTELIC Communications Inc Confidential Page 21 of 34 Kona Macro Gateway Dimensions Communes ...

Страница 22: ...p du connecteur Kona Gateway est détaillé dans la Figure pour le modèle T0004250 Tous les connecteurs ne sont pas présents sur d autres modèles Le connecteur d alimentation CC est remplacé par un connecteur de puissance fibre DC hybride sur des modèles qui prennent en charge la capacité de rétroaction de fibre comme avec le modèle T0004252 décrit en détail à la figure ...

Страница 23: ...EKTELIC Communications Inc Confidential Page 23 of 34 Kona Macro Gateway T0004250 Champ du connecteur GPS Antenna DC Power 2 pin CPC LoRa RF Antenna 1 LoRa RF Antenna 0 Enclosure Évacuation Terre de protection LED 3G 4G Modem Antenna Ethernet Cuivre ...

Страница 24: ... et leurs connecteurs correspondants sont répertoriés dans le Tableau Kona Macro Gateway Types de connecteurs d interface Interface QTY Connector Type Mating Connector LoRa Antenna Ports 1 or 2 N Type femelle Standard d industrie N Type male 3G 4G Modem Backhaul Antenna Port 0 or 1 N Type femelle Standard d industrie N Type male Copper Ethernet Port 1 Fileté circulaire RJ 45 Shenzhen Chogori Techn...

Страница 25: ...ct DC 48 VDC nominal plage de fonctionnement de 37 à 57 VDC après un seuil de démarrage maximal de 42 V Alimentation référencée au sol positive ou négative SELV source requise Protection maximale contre les surintensités d entrée 10A Alimentation PoE 802 3 à la classe 2 classe 4 mode A ou mode B mais limité à une longueur de câble maximale de 3 m et une tension de sortie PSE minimale de 56 V L ali...

Страница 26: ...na est considérée comme un équipement connecté en permanence La connexion à la terre de protection c est à dire la borne à deux trous à la masse du châssis est toujours requise Assurez vous que la connexion à la terre de protection Kona Macro Gateway est terminée correctement avant la connexion de toute autre interface La passerelle Macro Kona contient une protection contre les surtensions primair...

Страница 27: ...endu et doit être évitée La source d alimentation Kona Macro Gateway doit répondre aux exigences SELV 6 2 Déballage et inspection Les éléments suivants doivent être pris en compte lors du déballage d une nouvelle passerelle Kona Macro Inspectez le carton d expédition et signalez tout dommage important à TEKTELIC Le déballage doit être effectué dans un endroit propre et sec lorsque possible Ne jete...

Страница 28: ...gure Le module passerelle doit être orienté avec le connecteur Face vers le bas vers la terre Assurez vous que la structure sur laquelle la passerelle est montée est sécurisée et capable de supporter une charge mortelle d au moins 136 kg La zone ci dessous doit être exempte de tout obstacle à l entrée du câble Module Kona avec support de montage La procédure de montage mural Kona Macro Gateway est...

Страница 29: ... de 1 4 x 0 75 au point de terminaison du sol illustré à la Figure Le calibre du câble de masse doit être au minimum de 10 AWG Le système de mise à la terre Kona Macro Gateway doit respecter les codes électriques locaux et nationaux Le conducteur de mise à la terre de protection terminé au point de douille à double trou est obligatoire et doit être la première connexion à la passerelle Macro Kona ...

Страница 30: ...n continue en courant continu est isolée du châssis terre à l exception des capteurs de surtension primaires Un conducteur de l alimentation en courant continu est normalement référencé à la terre à l extérieur de la passerelle Kona Macro généralement à la source d alimentation par convention Le câble d alimentation CC doit être homologué pour une utilisation en extérieur conformément aux codes él...

Страница 31: ...e à un câble n est pas étanche à l eau et doit être collée pour être utilisée à l extérieur TEKTELIC recommande l utilisation d un adhésif Scotch Wireless Weatherproofing Kit WK 101 Suivez les procédures d enregistrement décrites par le fournisseur de ce système de bandes Notez que le port d antenne du modem 3G 4G n est pas protégé contre les surtensions et que par conséquent l antenne doit être s...

Страница 32: ...ersion 1 1 TEKTELIC Communications Inc Confidential Page 32 of 34 Le câble Ethernet doit avoir un minimum de conducteurs 24 AWG et doit être évalué pour une utilisation en extérieur conformément aux codes électriques locaux et nationaux ...

Страница 33: ...e connecteur Ethernet cuivre de cloison RJ45 Pour une installation alimentée en PoE un injecteur PoE peut être nécessaire Appliquez l alimentation CC à la passerelle Kona Macro On s attend à ce que le tirage de courant initial soit supérieur à 0 1 A S il n y a pas de courant la polarité de la connexion du câble d alimentation CC peut être inversée ou la source d alimentation peut ne pas être confi...

Страница 34: ...mal de 8dBi peut être utilisée pour les radios LoRa de ce produit si la perte d insertion de câble à 900 MHz est de 0 5dB ou plus pour une opération de porteuse à 28 5dBm ou 2dB ou plus pour un fonctionnement de 2 porteurs à 30dBm au total Une ou plusieurs antennes doivent être installées à un emplacement situé à au moins 31 5 pouces 80 cm de tout corps humain Pendant le fonctionnement du produit ...

Отзывы: