background image

 
 
 
 

© 2019 TEKTELIC Communications Inc., all rights reserved. 
All products, names, and services are trademarks and registered trademarks of their respective companies. 

 

TEKTELIC Communications Inc. 
7657 10

th

 Street NE 

Calgary, AB, Canada  T2E 8X2 
Phone: (403) 338-6900 

 
 
 
 
 
 
 

LoRa IoT Smart Room Sensor 

User Guide 

D

OCUMENT 

T

YPE

User Guide 

D

OCUMENT 

N

UMBER

T0006338_UG 

D

OCUMENT 

V

ERSION

1.5 

P

RODUCT 

N

AME

LoRa IoT Smart Room Sensor 

P

RODUCT 

C

ODE

T0006115 (Base Model, NA) 

T0006116 (PIR Model, NA) 

T0006117 (Base Model, EU) 

T0006118 (PIR Model, EU) 

T0006161 (Base Model, CN) 

T0006162 (PIR Model, CN) 

T0006163 (Base Model, DN) 

T0006164 (PIR Model, DN) 

R

ELEASE 

D

ATE

February 25, 2020 

 

Содержание LoRa IoT Smart Room Sensor

Страница 1: ...AB Canada T2E 8X2 Phone 403 338 6900 LoRa IoT Smart Room Sensor User Guide DOCUMENT TYPE User Guide DOCUMENT NUMBER T0006338_UG DOCUMENT VERSION 1 5 PRODUCT NAME LoRa IoT Smart Room Sensor PRODUCT CO...

Страница 2: ...pdated for battery type Updated for maximum output power Updated for Light Transducer operation Updated for Accelerometer operation Updated for PIR sense pattern for ceiling mount and wall mount lense...

Страница 3: ...Motion Detection PIR Transducer 13 1 3 5 Magnetic Switch 16 1 3 6 External Connection 16 1 3 7 Moisture Detection Transducer 18 2 Installation 20 2 1 Included Product and Installation Material 20 2 2...

Страница 4: ...LoRa IoT Smart Room Sensor User Guide T0006338_UG Version 1 5 TEKTELIC Communications Inc Page 4 of 30 4 4 Reset Button Function 25 5 Battery Replacement 26 6 Compliance Statements 28 7 References 30...

Страница 5: ...ion 1 5 TEKTELIC Communications Inc Page 5 of 30 List of Tables Table 1 1 Smart Room Sensor Models 7 Table 1 2 Smart Room Sensor Functional Variants 8 Table 1 3 Smart Room Sensor Specifications 10 Tab...

Страница 6: ...Transducer theoretical sense pattern with the ceiling mount lens 14 Figure 1 4 The PIR Transducer theoretical sense pattern with the wall mount lens 15 Figure 1 5 The alignment of PIR sense pattern w...

Страница 7: ...specific LoRaWAN region as indicated in Table 1 1 The Tx and Rx frequency plan for each model is a function of the LoRaWAN RF region and has been explained in 1 Each sensor has two labels at the back...

Страница 8: ...r to detect if it has been moved Light Detection Light transducer reports the presence or absence of light using a configurable intensity threshold Motion Detection PIR A top mounted PIR transducer de...

Страница 9: ...ugh only functional interfaces are exposed in the case of each model For example a Base model has been shown in Figure 1 2 which does not have the PIR element the PIR transducer indicated in the figur...

Страница 10: ...ential only Operating temperature 0 C 60 C 10 C 40 C for optimal battery life Storage temperature 30 C 60 C 0 C 30 C for optimal battery life RH 5 95 non condensing Size 42 mm x 42 mm x 17 mm enclosur...

Страница 11: ...t accuracy 4 between 0 and 100 2 between 20 and 80 Light sensitivity Detection of weak light to typical light conditions 5 lux to 1000 lux Peak sensitivity at 500 nm Accelerometer sensitivity 16 mg LS...

Страница 12: ...a transducer located in the Room Sensor microprocessor The Sensor can be configured to report temperature and RH values or to report alarms based on a customer configured normal operating window High...

Страница 13: ...plication for the appropriate trigger point The sample rate is also customer settable with higher sample rates increasing battery consumption 1 3 4 Motion Detection PIR Transducer The Room Sensor PIR...

Страница 14: ...o that the subjects move across its FoV and not towards or away from the Sensor The sense pattern alignment to the Room Sensor body for the ceiling mount lens is shown in Figure 1 5 The X and Y ranges...

Страница 15: ...oRa IoT Smart Room Sensor User Guide T0006338_UG Version 1 5 TEKTELIC Communications Inc Page 15 of 30 Figure 1 4 The PIR Transducer theoretical sense pattern with the wall mount lens 5 m View 4 m Vie...

Страница 16: ...nctionality The switch function can be configured to sense open to close events close to open events or both types of events For example if the Sensor is being used for sensing access to a door and is...

Страница 17: ...b based on a desired criterion e g MMSE minimum mean square error or minmax criterion For example for CWF3AA103G3380 and NTCAIMME3 using the MMSE criterion the conversion formulas 3380 ln 0 00314 0 0...

Страница 18: ...T exceed 3 meters See Section 2 6 for the connector pin assignment and cable installation Table 1 4 Smart Room Sensor Interface Connector Types Interface Sensor Connector Mating Jumper Cable 300mm Ext...

Страница 19: ...ser Guide T0006338_UG Version 1 5 TEKTELIC Communications Inc Page 19 of 30 values 16 32 64 or 128 seconds Smaller sample periods faster sampling uses more energy and shortens battery life The default...

Страница 20: ...not close securely stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention To red...

Страница 21: ...attaches to the 2 pin connector located on the top of the sensor Figure 2 1 shows the external connector pinout In the digital mode the connector is designed to be attached to an open drain output how...

Страница 22: ...t Room Sensor User Guide T0006338_UG Version 1 5 TEKTELIC Communications Inc Page 22 of 30 Figure 2 2 The cable clip to be attached to the Base model as shown should a cable be connected to the Extern...

Страница 23: ...n the Smart Room Sensor 3 2 Power Up Down Procedure Once the sensor information has been added to the Network Server pull out the battery tab to engage the battery To turn off the device the battery m...

Страница 24: ...PIR Room Sensor is Report Temperature Humidity and Battery Voltage every one 1 hour Report the PIR status o When PIR first detects motion o When PIR has stopped detecting motion for more than five 5 m...

Страница 25: ...d via the downlink command interface NOTE Any other LED pattern behaviour not described above most likely indicates a low battery For example if steps 1 2 repeat continuously the battery no longer has...

Страница 26: ...y stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention Use only approved CR2477...

Страница 27: ...then taking the cell from the other end and pulling it out as indicated in the image below Place the new cell in the holder The top of the coin cell is marked with a symbol indicating the positive ter...

Страница 28: ...ovide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance...

Страница 29: ...anada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage 2 L appareil doit accepter tout brou...

Страница 30: ...ommunications Inc Page 30 of 30 7 References 1 LoRa Alliance LoRaWAN 1 02 Regional Parameters Revision B Feb 2017 2 TEKTELIC Communications Inc LoRa IoT Smart Room Sensor Technical Reference Manual TR...

Отзывы: