Kona Micro Outdoor User Guide
T0005158_UG
Version 0.34
TEKTELIC Communications Inc.
Confidential
Page 14 of 32
Figure 5: Chassis Ground Connection
2.6
Direct DC Power Cable Installation
The Kona Micro Outdoor Gateway direct DC feed terminates at a dedicated two pin circular
plastic connector (CPC) on the bulkhead. The direct DC power input is isolated from chassis
(earth) with the exception of the primary surge suppressors. One lead of the DC power feed is
normally earth referenced external to the Kona Micro Outdoor Gateway (usually at the power
source by convention).
The DC power cable shall be rated for outdoor application according to local and national
electrical codes.
The CPC direct DC connector shall be as specified in Table 2 and shall follow the signal polarity
identified in Figure 6.
Chassis Ground
Connection