A Lightning Protection device may be inserted into the antenna lead. A suitable device
complete with additional cable connectors, a connector crimping tool and mounting
hardware is available as an option (see Section 7.3 on page 16). Introduction of the
Lightning protector does not degrade the performance of the antenna system.
5.3
P2, P3: Outputs
5.3.1 Electrical and Physical Configuration
F
Figure 5 – 2pin
connectors
Figure 6 – BNC
connectors
Figure 7 – Fibre
connectors
Each output port may be fitted at the factory according to the following:
Electrical
Electrical Specification
Physical
TTL
CMOS/TTL (5V) logic level driver output ports, 150mA sink
and source. The port is fully floating and has independent
electrical isolation to 2.5kV
2-pin
or BNC
RS422
High Speed RS422 compliant output ports. The port is Fully
floating and has independent electrical isolation to 2.5kV.
2-pin
or BNC
HV
MOSFET
Power MOSFET Switch, allowing switching of 300VA, 1A max.
The port is fully floating and had independent electrical
isolation to 2.5kV. See the detail in Section 7.1 on page 15 for
suggested wiring configurations for use with Power MOSFET
switching.
2-pin
Fibre
ST fibre transmitters, compatible with ST-terminated 62.5
ȝ
m
fibre diameter, 125
ȝ
m jacket diameter multi-mode fibre optic
cabling. The maximum length of fibre recommended is 700
metres.
ST Fibre