87
Status
LEDs
Onset Conditions
ALARM
RADIO
NETWORK
No communication
with Control Panel
Blinks
yellow
twice
a second
-
No data exchange via RS-485 interface due
to interface failure
Failure / RF jamming
Blinks
yellow
once
a second
-
RF jamming
Communication via ra-
dio network
-
Blinks white
Any notification or a command via radio
17.3 HARDWIRED ZONES EXTENDER ASTRA-713
LED
Status
LED
« »
Onset Conditions
Power normal
Lights
green
const.
Supply voltage is normal, from 11.5 to 15 V
Power failure
Blinks
red
once per second.
Pulse duration is 0.5 sec
Supply voltage is below normal, from 11.5 to 10.2
V
Fast blinking
red
in sync with the
indicators "1" - "8"
Supply below 10.2 V (inoperability status)
Status
LED «1» - «8»
Onset Conditions
HE not registered
All not lit
HE not registered or registration data are cleared
as a result of device reset to default settings
Communication - normal
All light
green
const.
Data exchange via RS-485 interface is normal
No communication with
Control Panel
All blink
red
twice a second.
Pulse duration 0.25 sec.
No data exchange via RS-485 interface due to in-
terface failure
Fast blinking
red
in sync with
LED
« »
No data exchange via RS-485 interface due to
supply voltage decrease below 10.2 V
Содержание ASTRA ZITADEL
Страница 3: ...3 15 EVENT LOG 72 16 SYSTEM USERS 75 17 LED INDICATION 85...
Страница 21: ...21 6 2 ASTRA 8945 PRO COMMON WIRING DIAGRAM...
Страница 22: ...22 6 3 WIRING DIAGRAM FOR SYSTEM COMPONENTS...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 73: ...73 3 Click Apply 4 Click Report icon to create a report...
Страница 74: ...74 5 Click icon to create a list of events per shift...