Step-16 

     

Install jumpers on 

Ind

 plug

 

and 

Mem 

plug

 

depending on selected operating 

mode.

 

 

 

 

 

Step-17

 

 
Install  detector  cover  in  its 
place (until the click)

 

 

Step-18   

If during alarm system testing in the initial operation period 
(1-

2 weeks) there are generated false “Alarm” notifications 

connected  with  peculiarities  of  the  secured  room,  one 
should remove jumper from 

Sens 

plug. 

 

 

 

 

8.5 

To  provide  fail-safe  operation  of  alarm  system  it  is 

recommended  to  carry  out 

testing

  and 

maintenance

  of  the 

detector 

at least 1 time per month

.

 

Testing should be carried out as follows: 

-

  Perform moving through detection zone; 

-

 

Check output of "Alarm” notification  on control panel and on 

indicator  if  indication is enabled  (indicator  lights  on  1  time for 
4s at every movement). 
Maintenance should be performed as follows: 

inspect  integrity  of  the  detector’s  body,  reliability  of  contact 

connections, 

detector 

fixation; 

clean 

detector 

from 

contamination. 

 

9  Labeling 

 

On a label attached to the case are indicated: 
- abbreviated marking of the detector; 
- firmware version; 
- month and year (last two digits) of manufacture; 
- conformity mark (if certificate is available); 
- barcode, duplicating text information

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10  EC Conformity Declarations 

 

This product is in conformity with the provisions of: 
EMC 89/336/EEC 
EN  61000-6-3:2005  Electromagnetic  compatibility  (EMC)  -  Part  6-3: 
Generic  standards  -  Emission  standard  for  residential,  commercial 
and light-industrial environments 
EN 50130-4/1995 + A1:1998 + A2:2003 + Corrig. 2003 Alarm systems 
-  Part  4:  Electromagnetic  compatibility  -  Product  family  standard:  Im-
munity requirements for components of fire, intruder and social alarm 
systems 
EN 60950-1: 2001+A11:2004+Corrig.2004 Safety of information tech-
nology equipment 

 

11  Recycling 

 

Detector is not dangerous for life and health of people and is safe for 
environment,  after  termination  of  service  life  it  should  be  recycled 
without special environment protective measures

 

12  Warranty 

 

12.1  Quality  Management  System  meets  provisions  of  ISO  9001-
2011. 
12.2 The manufacturer provides requirements compliance of detector 
in  condition  of  observance  of  technical  requirements  concerning 
transportation, storage, mounting and operating the detector. 
12.3 The storage warranty time is 5 years and 6 months from the date 
of manufacturing. 
12.4 The operation warranty time is 5 years from the date of operation 
start-up but no longer than 5 years 6 months from the date of manu-
facturing. 
12.5  The manufacturer  commits to  replace  or  repair the  product  dur-
ing the warranty period. 
12.6 The warranty does not come into effect in following cases: 
-operation manual is missing; 
-mechanical damage of the product; 
-repair of the detector by any other party except the manufacturer. 
12.7  This  warranty  applies  to  the  detector  only,  not  to  equipment  of 
third part manufacturers used with the detector jointly. 
12.8  User  should  keep  in  mind  that  correctly  installed  signaling  sys-
tem serves to decrease the risk of such events as larceny, robbery or 
fire, but not to avoid them at all. 

The  manufacturer  bear  no  responsibility  for  death,  injury, 
damage  of  property  or  any  other  kinds  of  accidental  or 
premeditated  damages,  based  on  user’s  statement  that  device 
failed to implement its function. 

 

 
 

Sales: 

Controlex GmbH

 

Warranty service and  
technical support: 

ТЕКО-TD 

 

Philosophenweg 31-33 
47051 Duisburg, Germany 
Phone: +49 (0) 203 / 393 91 188 
Fax:     +49 (0) 203 / 393 91 189 
GSM:   +49 (0) 178 / 218 48 22 
E-mail: 

[email protected]

  

Web:    

www.controlex.eu

 

 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
Phone: +7 (843) 261-55-75 
Fax:     +7 (843) 261-58-08 
E-mail: 

[email protected] 

            [email protected]

 

Web:    

www.teko.biz

  

 

Made in Russia

 

 

 

Содержание Astra-6

Страница 1: ...cal Channel Detection range m not exceeding 12 Detection area volume with viewing angle in horizontal plane 12 12 Range of detected moving speed m s from 0 3 up to 3 0 Resistance to ambient light lx not less than 6500 Recommended height of installation m from 2 4 up to 2 5 General Technical Parameters Power supply voltage V from 8 up to 15 Current consumption in stand by mode and in Alarm mode mA ...

Страница 2: ...is activated in 1 minute after installation of Mem plug or in 1 min after starting of detector stand by mode with jumper installed previously on Mem plug Alarm notification is indicated in 1 min after violation of protected area To switch the mode off and reset indication remove jumper from Mem plug or switch power off TEST pass allows revealing precise location of sensitive zones formed by the le...

Страница 3: ...al terminal RES is provided Step 9 Using sealing material of distribution kit seal hermetically wire insertion hole and other holes to protect detector from air and insects ingress Step 10 Install jumper on Ind plug and Sens plag Remove jumper from Mem plug Step 11 Power detector up indicator flashes 1 time per 1 s during 60s starting of detector working mode Step 12 During starting of detector wo...

Страница 4: ...y equipment 11 Recycling Detector is not dangerous for life and health of people and is safe for environment after termination of service life it should be recycled without special environment protective measures 12 Warranty 12 1 Quality Management System meets provisions of ISO 9001 2011 12 2 The manufacturer provides requirements compliance of detector in condition of observance of technical req...

Отзывы: