18
Figure 13
7.
The capture will be performed in the same window the length and width of the field where information must be
entered.
8.
Must be entered step size at the same window. Program will calculate sample periods and sample ways with
using size of the area and step size. Step size is choosible due to user need.
9.
The above settings are done, it should be located at the lower left side of the display area. In the process of the
shooting area of the imaging start shooting left six, finishing the shot on the right is the shadow. How to do the
sampling during shooting are shown in Figure 8. When switched to the lower left corner of the shooting settings
on the screen shot select the OK button. An image comes on the screen as shown in Figure 9 The result of this. The
region circled in red here your shots during a match the nth sample path and in that path that were in the shows.
The Cancel button also at the end of the path next to the road under the direction of the
Direction Change!
In the
form of a warning the next part is located. Point to note here is that the sample was taken and how many how
many ways change the way and be known! The other way to pass an alert must be known. When these guidelines
are followed tread a path as shown in Figure 8. The 3D button on the main unit button during shooting will be
used as the sampling detector. During shooting, when each button is pressed, the image on the tablet screen from
the current position to the corresponding location in the received data by adding the attraction takes place in a
concurrent manner. The final version of the image on the screen will appear when shooting is complete.
Attention! The diameter of the coil have to be erased and rewritten even though the tab is correct.
Attention! The sensor of the radiometer is determined by looking at the directional buttons. The buttons look in
the direction of North or South when the north began shooting and during shooting always if you look at the
north, when the South began shooting during shooting, if you look at always should be positioned facing south.
Attention! Shooting to be done with the sensor in position and the position of the radiometer is of great
importance. This location and position the location and position should be kept as far as possible during reset.
Attention! He wants the user that will use filtering to get the image shooting section. Therefore there is a value
that should be. The user should choose the values to be selected depending on their request.
The Meanings Of The Filter
1
- December filter: this filter works only for this range and selecting the range of the desired signal to be
displayed.
2
- in depth filter: this filter works to strengthen the signal within the desired range of the desired rate.
3
- filter surface: on the surface of the metal resulting from the abolition of benefit from a very high perception.
4 - Separation filter: with only perceived as valuable to be displayed on the screen of metal detection works.
Содержание Delta Pulse 3S Plus
Страница 1: ...1 User Manuel...
Страница 6: ...6 8 Gradiometer 9 Tablet PC Figure 1...
Страница 20: ...20 Gradiometer opened and closed ares Metal Detector Small Metal Gradiometre iron...
Страница 22: ...22...