![TEKNIX TKGF51TBL Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/teknix/tkgf51tbl/tkgf51tbl_user-manual_1076948024.webp)
2
4
Reduced gas flow rate setting for hob taps
1.
Ignite the burner that is to be adjust
ed
and turn the knob to the
reduced position.
2.
Remove the knob from the gas tap.
3.
Use an appropriately sized screwdriver to adjust the flow rate adjustment
screw. For LPG (butane-pro pane) turn the screw clockwise. For the
natur
a
l gas, you should turn the screw counter- clockwise once.
“The normal length of a straight flame in the reduced position should
be 6-7 mm.“
4.
If the flame is higher then the desired position, turn the screw clockwise.
If it is smaller turn anti
c
lo
ckwise.
5.
For the last control, bring the burner both to hig
h
-flame and reduced
positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment
screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for
reduced flame carefully by turning with a small screwdriver as shown
below on the screw in the middle of the gas cocks as well as nozzle
changes. (figure 3 and 4)
Figure 3