![Teknion D06-4726 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/teknion/d06-4726/d06-4726_user-instruction_1076928005.webp)
Http://www.czkaidi.com
- 4 -
12.
Error code
Step
Operation
Motion
E01
Leg malfunction
1.
legs loosed to the control box, check the cable connection, ensure the
connection.
2.
Inner parts of legs are broken, replace the legs
E03
Table top overload
1. Too many loads on table top, remove the loads.
E04
Control box malfunction
1.
under extreme environment, operating will cause the control box
malfunction, initial procedure needed
2.
discontinue the initialize process will cause the control box malfunction,
reinitialize needed.
E05
Button of switch stuck
1.
button of switch stuck, check the status of the button, if stuck then toggle
the button to restore.
2.
Replace the switch
E06
Communication disconnected
1.
Disconnection between switch and control box, ensure the connection
correctly
2.
Check the control box works correctly
E07
Lower setting of switch verifying height
1.
switch setting height is low, the height value is below 0, needs to adjust the
height, lift the table
E08
Electrical short circuit
1
Check whether the motor cable is damaged, and replace the motor cable if
necessary
2.
2. Power on again. If the fault does not disappear, check whether the motor
is working properly
E09
Abnormal HALL
1 . Re-initialization can be used normally
E10
Drive anomalies
1. Cut off the power supply to cool the control box for 1 minute and re-power
it. If the fault does not disappear, the control box need be replaced