Teknion D06-4726 Скачать руководство пользователя страница 5

Http://www.czkaidi.com

 

- 4 - 

12.

 

Error code 

Step 

Operation 

Motion 

E01 

Leg    malfunction 

1.

 

legs loosed to the control box, check the cable connection, ensure the 

connection. 

2.

 

Inner parts of legs are broken, replace the legs 

E03 

Table top overload 

1.      Too many loads on table top, remove the loads. 

E04 

Control box malfunction 

1.

 

under extreme environment, operating will cause the control box 

malfunction, initial procedure needed 

2.

 

discontinue the initialize process will cause the control box malfunction, 

reinitialize needed. 

E05 

Button of switch stuck 

1.

 

button of switch stuck, check the status of the button, if stuck then toggle 

the button to restore. 

2.

 

Replace the switch 

E06 

Communication disconnected 

1.

 

Disconnection between switch and control box, ensure the connection 

correctly 

2.

 

Check the control box works correctly 

E07 

Lower setting of switch verifying height 

1.

 

switch setting height is low, the height value is below 0, needs to adjust the 

height, lift the table 

E08 

Electrical short circuit 

1

 

  Check whether the motor cable is damaged, and replace the motor cable if 

necessary 

2.

 

2. Power on again. If the fault does not disappear, check whether the motor 

is working properly 

E09 

Abnormal HALL 

1 .      Re-initialization can be used normally 

E10 

Drive anomalies 

            1.    Cut off the power supply to cool the control box for 1 minute and re-power 

it. If the fault does not disappear, the control box need be replaced 

 

 

Содержание D06-4726

Страница 1: ...Guide no DIS_001 Date Sept_2020 District User Instruction Display Switch w Memory D06 4726 Note Please Use the Below Mentioned Instruction to Setup the Display Switch ...

Страница 2: ...ization procedure must be completed before the first running after table is installed or parts replaced 2 Move up and down Step Operation Motion 1 Press and hold Legs move up 2 Release Legs stop 3 Press and hold Legs move down 4 Release Legs stop 3 Set memory positions 1 2 3 Step Operation Motion 1 Press and hold or then release Run the legs to the position you want the table surface to be 2 Click...

Страница 3: ...witch data to table height Step Operation Motion 1 Set the table at any height recommended at the bottom position Measure the table actual height and write down the number in inches or in centimeters 2 Press and hold button S then press and hold keep about 3 seconds The first number is flashing on the screen 3 Release the buttons then click or to change the first number The first number is being i...

Страница 4: ...sition that the table can be moved to 3 Release the buttons Completed 1 Legs aren t able to run above the locked position 2 Memory position s above the locked position will lost even after the table is unlocked you need to follow SET MEMORY POSITIONS again to reset these memory positions 3 Initialize will not unlock the top limit 10 Unlock the top bottom stroke Step Operation Motion 1 Press and ho...

Страница 5: ...if stuck then toggle the button to restore 2 Replace the switch E06 Communication disconnected 1 Disconnection between switch and control box ensure the connection correctly 2 Check the control box works correctly E07 Lower setting of switch verifying height 1 switch setting height is low the height value is below 0 needs to adjust the height lift the table E08 Electrical short circuit 1 Check whe...

Страница 6: ... not Please contact with your supplier The legs don t move according to your operation Please contact with your supplier One leg moves while the other leg does not move Check if the connection is correct or not Please contact with your supplier Legs only move down and don t move up Re initialize the table Please contact with your supplier Table slides down itself Check if the weight of the load on...