background image

Http://www.czkaidi.com

 

- 2 - 

5.

 

    Turn on/off the one touch key function 

Step 

Operation 

Motion 

Press key “S” for more than 5 seconds 

Screen flashes “---” 

Release key “S”, then press key”1” in 3 seconds. 

Letter “H-0” or “H-1”

 

is indicated on the screen. That means the function is turned on or 

turned off 

Press 

  or 

  to modify the function 

“H-0” shows the function is turned off, “H-1” shows the function is turned on. 

Press key “S” for 2 seconds 

completed 

1. Tacitly approve the one touch key function is turned off. 

 

 

 

6. Toggle the display unit format 

Step 

Operation 

Motion 

Press  and  hold  button  S,  then  press  and  hold

, keep about 3 seconds 

The height information will be changed between centimeters and inches   

Release the buttons 

completed 

  In inch format, the minimum height variation as the legs move up or down is 0.5 inches, while in centimeter format is 1 centimeter 

 

 

 

7. Verify the display switch data to table height 

Step 

Operation 

Motion 

Set  the  table  at  any  height,  recommended  at 

the bottom position   

Measure  the  table  actual  height  and  write  down  the  number  in  inches  or  in 

centimeters   

Press  and  hold  button  S,  then  press  and  hold 

, keep about    3    seconds 

The first number is flashing on the screen   

Release  the  buttons,  then  click 

or

  to 

change the first number   

The  first  number  is  being  increased  or  decreased  to  the  first  number  you 

measured 

Click button S 

The second number is flashing on the screen 

Click 

or

  to change the number 

The  second  number  is  being  increased  or  decreased  to  the  second  number  you 

measured   

Click button S 

The third number is flashing on the screen 

Click 

or

  to change the number 

The  third  number  is  being  increased  or  decreased  to  the  third  number  you 

measured 

Click button S 

Completed 

 

Check the switch display format in inches or in centimeters and toggle to the unit you like and match to the actual measurement. In inch format, the 

minimum adjustable height is 0.5 inches, while in centimeter format is 1 centimeter. 

 

 

 

 

 

 

 

Содержание D06-4726

Страница 1: ...Guide no DIS_001 Date Sept_2020 District User Instruction Display Switch w Memory D06 4726 Note Please Use the Below Mentioned Instruction to Setup the Display Switch ...

Страница 2: ...ization procedure must be completed before the first running after table is installed or parts replaced 2 Move up and down Step Operation Motion 1 Press and hold Legs move up 2 Release Legs stop 3 Press and hold Legs move down 4 Release Legs stop 3 Set memory positions 1 2 3 Step Operation Motion 1 Press and hold or then release Run the legs to the position you want the table surface to be 2 Click...

Страница 3: ...witch data to table height Step Operation Motion 1 Set the table at any height recommended at the bottom position Measure the table actual height and write down the number in inches or in centimeters 2 Press and hold button S then press and hold keep about 3 seconds The first number is flashing on the screen 3 Release the buttons then click or to change the first number The first number is being i...

Страница 4: ...sition that the table can be moved to 3 Release the buttons Completed 1 Legs aren t able to run above the locked position 2 Memory position s above the locked position will lost even after the table is unlocked you need to follow SET MEMORY POSITIONS again to reset these memory positions 3 Initialize will not unlock the top limit 10 Unlock the top bottom stroke Step Operation Motion 1 Press and ho...

Страница 5: ...if stuck then toggle the button to restore 2 Replace the switch E06 Communication disconnected 1 Disconnection between switch and control box ensure the connection correctly 2 Check the control box works correctly E07 Lower setting of switch verifying height 1 switch setting height is low the height value is below 0 needs to adjust the height lift the table E08 Electrical short circuit 1 Check whe...

Страница 6: ... not Please contact with your supplier The legs don t move according to your operation Please contact with your supplier One leg moves while the other leg does not move Check if the connection is correct or not Please contact with your supplier Legs only move down and don t move up Re initialize the table Please contact with your supplier Table slides down itself Check if the weight of the load on...

Отзывы: