In this particular mode, ClearPath must perform a homing operation (all
of your target positions are defined in terms of distance from the "home"
easy, and only
tion).
AKING A
M
OVE
itable switching
e
Output (we call it HLFB for High-Level Feedback) can be
configured to signal when ClearPath completes a move, reaches a
specified speed or torque, or has shut itself down for safety reasons. See
the section on High-Level Feedback for complete details.
O
VERVIEW
:
C
ONFIGURING A
C
LEAR
P
ATH
ClearPath must be configured and tuned before it can be used
in a motion application. The main configuration steps are outlined
below. Each of these points is discussed in greater detail later.
1.
Install ClearPath software (MSP) on a qualified Windows PC.
2.
Connect your I/O devices to ClearPath (switches, PLC,
microcontroller, etc.).
3.
Supply DC power (24-75VDC) to ClearPath.
4.
Connect ClearPath to your PC with a standard USB cable.
5.
Use ClearPath MSP software to:
a.
Select a mode of operation.
b.
Set motion parameters and options (acceleration,
velocity, torque, safety settings, etc.).
c.
Tune the motor/mechanical system.
ttings as needed to optimize quality of
motion and overall system performance.
reference position). Setting up your homing parameters is
has to be done once (using the included MSP software).
After homing is complete, ClearPath can be commanded to move to any of
the predefined positions by changing the state of Inputs A and B (see table
in previous figure: ClearPath Input States vs. Target Posi
E
XAMPLE
:
M
Motion objective: Move the load platform from target position#1 to
target position #4.
User action: Simultaneously set Inputs A and B high. This can be done
with toggle switches, PLC, microcontroller, or other su
devices.
Motion result: The motor immediately executes a smooth, crisp mov
per the user’s acceleration and velocity settings. The motor decelerates
and settles at position #4. Note: ClearPath will actively servo to maintain
position until another move command is received, unless the system is
intentionally disabled, powered down, or in a shutdown state.
The Digital
6.
Test and adjust se
7.
Disconnect the computer, cover USB port with the included
silicone plug, and run your application. No computer is
needed once setup is complete.
Save your settings! You can save your ClearPath settings to a motor
configuration file—the file extension is .mtr—at any time. This allows you
to easily test and compare various sets of tuning parameters. And, if you
build many machines of the same design, you’ll appreciate how quickly
you can load a saved configuration file into a new ClearPath.