background image

I P C - 3 ,

 

I P C - 5

 

U

S E R  

M

A N U A L  

R

E V

.

 

2 . 0 3  

1 5

 

 

 

T

EKNIC

,

 

I

NC

 

P

HONE 

(585)784-7454 

A

PPENDIX 

C:

 

M

ECHANICAL 

R

EFERENCE

 

M

OUNTING 

D

IMENSIONS 

(IPC-3

 AND 

IPC-5) 

 60.5 

 14.15 

 9.23 

 36.0 

 11.0 

 160.0 

[6.3]

[1.417] 

 39.7 

[1.563] 

 36.7 

[1.445] 

[2.382] 

[.433] 

[.557] 

[.363] 

 80.0 
[3.15]

B

B

A

A

A

B

Dia. 3.45mm [.136”]
Qty.3, 8-32 UNC-2B
Max. penetration into 
case = 6.35mm [0.25”] 

B

*

Note: Size “A” holes are provided 
for use with optional DIN rail 
adapter bracket, 

Phoenix UTA-89 

(

not sold by Teknic.)

UP

Dia. 2.50mm [.098”]
Qty. 3, M3 x 0.5 - 6H
Max. penetration into 
case = 5.5mm [0.22”]                   

A

Mounting holes for optional 
DIN rail adapter (see note*)

Holes for direct mount

Tol. 1

Tol. 2

Tol. 2

Tol. 1

Tol. 1

Tol. 1

Tol. 1

Tol. 1

Units: 

mm  [inches] 

Tol. 2

Tol. 2

Mechanical Tolerances

+/- .008 in.

+/- .203 mm

Tol. 1

+/- .015 in.

+/- .381 mm

Tol. 2

 

Содержание Amazon IPC-3

Страница 1: ...USER MANUAL T E K N I C I N C P H O N E 5 8 5 7 8 4 7 4 5 4 IPC 3 AND IPC 5 POWER SUPPLIES VERSION 2 03 MAY 18 2020 ...

Страница 2: ...2 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 3: ...o Connect IPC To A Load 11 How To Disconnect IPC From A Load 11 Additional Use Notes 11 CABLES 12 IPC 3 IPC 5 Accessory Cables 12 APPENDIX A LED CODES 13 APPENDIX B SPECIFICATIONS 14 APPENDIX C MECHANICAL REFERENCE 15 Mounting Dimensions IPC 3 and IPC 5 15 Mounting a Third Party Fan IPC 5 Only 16 Top Mount Fan 40mm x 40mm 16 Side Mount Fan 80mm x 80mm 17 DIN Rail Adapter Optional Third Party 18 AP...

Страница 4: ...e weight and machine cost as well IPC 5 IPC 3 Amazon IPC 3 and IPC 5 Power Supplies FEATURES 75 VDC output with tight regulation even with large peak loads Dual AC input voltage ranges 95 125VAC 190 250VAC High peak output relative to continuous output rating 2 5x optimized for servo drive peak demand requirements Rapid output bus discharge upon AC power removal Built in automatic regenerated powe...

Страница 5: ...personal injury or loss of life Hazardous voltage Contact may cause electric shock burn or electrocution Hot surface Identifies presence of a burn hazard Protective earth terminal Indicates points that must be connected to a reliable earth system for safety compliance Protective earth connections should never be omitted Earth ground terminal Frame or chassis terminal Direct Current DC Alternating ...

Страница 6: ... the product GENERAL DISCLAIMER The User is responsible for determining the suitability of this product for their application The User must ensure that Teknic s products are installed and utilized in accordance with all local state federal and private governing bodies and meet all applicable health and safety standards Teknic has made all reasonable efforts to accurately present the information in...

Страница 7: ...me power supplies IPC 3 Power Supply GENERAL SAFETY INSTRUCTIONS Read these instructions Keep these instructions Heed all warnings Do not use this apparatus near water Clean apparatus with a clean dry cloth Do not block any ventilation openings Install in accordance with manufacturer s instructions Do not install near a heat source If sheet metal cover is damaged immediately disconnect apparatus f...

Страница 8: ...on switch or mechanism to ensure that unplugging the AC line cord is not the sole means of disconnecting AC mains power to the device and downstream equipment This apparatus shall be connected to a mains socket outlet with a protective earthing connection To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Apparatus shall not be exposed to dripping or spla...

Страница 9: ... Output Mating Connector Housing Molex 39 01 2080 Terminals Molex 39 00 0039 Crimp Tool Molex 638190900 Cable 18AWG 300V stranded WIRE ENTRY VIEW 5 1 6 2 7 3 8 4 AC Input Mating Connector PE GND pins 6 or 7 AC Hot AC Neutral Blink patterns here indicate status of regenerative energy management system See LED codes section for details Blink patterns here indicate various operational issues See LED ...

Страница 10: ...est convection cooling Allow a minimum 2 clearance above IPC Allow at least 1 clearance at sides and bottom Do not mount IPC above a heat source such as a spindle drive or heating element Do not mount IPC in an unventilated enclosure or where the ambient air temperature will exceed 40ºC See Mechanical Appendix for complete mounting dimensions 2 1 1 1 Best Mounting Orientation 2 1 1 1 DO NOT MOUNT ...

Страница 11: ...e or ClearPath motor Apply AC power to supply HOW TO DISCONNECT IPC FROM A LOAD Remove AC power from supply Disconnect DC power cable from the load ADDITIONAL USE NOTES IPC 3 5 supplies are not designed to operate in series or parallel configurations Do not wire these power supplies together in any configuration Always use the recommended wire gauge or larger for all cables connected to an IPC pow...

Страница 12: ...knic Part IPC35 CABLE110 Description Power cable Sabre to Sabre From IPC to Eclipse or Meridian 4xx 5xx series drives 72 in length nominal 72 Teknic Part PC SBR 72 Description Power cable Sabre to Molex Minifit Jr 4 position plug From IPC to ClearPath Motor 120 in length nominal 120 Teknic Part CPM CABLE PWR MS120 Description AC line cord 110V for Amazon IPC 3 and IPC 5 power supplies Includes NEM...

Страница 13: ...ceeded Action required This latching signal indicates that the power supply s ability to absorb regenerated energy was exceeded at least once since AC power was applied When this occurs the regen control circuit is automatically disabled as a protective measure but the DC output is still on Solution Upgrade to higher regen capacity supply Note This blink code will persist until AC power is cycled ...

Страница 14: ...0Hz Ripple 500mV P P zero to full load Min equivalent startup load 16 ohms AC input 105 210V min Output Resistance 300 milliohms Physical Weight 2 11 lbs 2 25 lbs Dimensions 181mm x 132mm x 57 3mm 183mm x 132mm x 57 3mm Finger Safe No User must be protected from shock hazard Yes Enclosure None Perforated epoxy coated aluminum Operating Environment Temperature Range 0 40 C Humidity 10 90 non conden...

Страница 15: ... 136 Qty 3 8 32 UNC 2B Max penetration into case 6 35mm 0 25 B Note Size A holes are provided for use with optional DIN rail adapter bracket Phoenix UTA 89 not sold by Teknic UP Dia 2 50mm 098 Qty 3 M3 x 0 5 6H Max penetration into case 5 5mm 0 22 A Mounting holes for optional DIN rail adapter see note Holes for direct mount Tol 1 Tol 2 Tol 2 Tol 1 Tol 1 Tol 1 Tol 1 Tol 1 Units mm inches Tol 2 Tol...

Страница 16: ...ctive hardware to secure fan to case such as plastic or rubber screws rubber fan push pins or similar by manufacturers such as Nexus and Lamptron Select an open corner open frame fan for easier mounting Select a fan with a CFM rating of 15 or greater Install fan such that air is drawn air out of the case Do not install fan to blow air into the case Fans require an external power source typically 1...

Страница 17: ...FAN 80MM X 80MM 12 6 11 94 71 5 71 5 3x Ø 4mm Mounting hole pattern for 80mm side mount fan IPC 5 shown with optional 80 mm side mount fan 80mm fan No screw here NOTE DO NOT DRILL INTO CASE Use only the 3 mounting holes indicated to attach fan to case UNITS mm Side mounted 80mm IPC 5 case fan ...

Страница 18: ...ur DIN rail is screwed directly to a solid wall or cabinet you may need to install standoffs to provide clearance for mounting and removing the unit See illustration below Use only three mounting screws and standoffs No screw here Standoffs unthreaded qty 3 Metric Length 10mm Inner diameter 3mm English Length 3 8 Inner diameter 3mm Screws for use with standoffs qty 3 Metric M3 x 0 5 Class 6H lengt...

Страница 19: ...t with 110 VAC power 5 1 6 2 7 3 8 4 PE Ground green yellow AC Line brown AC Line blue Remove this jumper if supply is to be powered by 190 250 VAC mains power 1 OR 5 1 6 2 7 3 8 4 5 1 6 2 7 3 8 4 How to remove or cut jumper wire for use with 190 250 VAC only NOTE Disconnect cable from AC before attempting to modify TERMINAL PULL WIRE AND TERMINAL SLOTS FOR EXTRACTOR TOOL HOUSING EXTRACTOR TOOL MO...

Страница 20: ...ilter and the IPC 3 5 Keep the connections as short as possible for best performance If connections must be greater than 12 long consider using shielded cable AC Line Filter Installation Recommended AC Line Filter Mfg EPCOS TDK Part B84112G0000B110 PE 75 VDC A representative system was proven to comply with EN55011 class A conducted emissions standards L1 L2 PE AC Line Filter AC In DC Out EPCOS TD...

Страница 21: ...I P C 3 I P C 5 U S E R M A N U A L R E V 2 0 3 21 TEKNIC INC PHONE 585 784 7454 Teknic Incorporated 115 Victor Heights Pkwy Victor NY 14564 2020 TEKNIC INCORPORATED ALL RIGHTS RESERVED ...

Отзывы: