Displa

y

Rang

e

A

ccess

Description

Set t

o

H1H1

AD

JUST

AD

JUST

SUPPL

Y

OFF or On

Def

ault = OFF

Installer

HEA

T SUPPL

Y PUMP DEL

A

Y

Dur

in

g heatin

g

, sele

ct

 whether or no

t the s

yst

em sup

p

ly

 

p

u

m

p

 shoul

d b

e

 d

e

la

ye

d b

y 3 minutes b

e

fore c

o

min

g

 

on (

for ther

mal motor or wa

x ac

tuator

).

A

vaila

b

le when

:

A r

ese

t contr

ol is pr

esent on t

he t

ekmarNe

t

®

 sy

st

em.

Au

to

,

S

Yn(Synchr

oniz

e)

Def

ault = 

Sy

chr

oniz

e

Installer

HEA

T CY

CLES PER HOUR

Select eit

her A

u

to

 cy

cle or Synchr

oniz

e wit

h o

ther

 

thermostats on t

he t

ekmarNe

t

®

 sy

st

em.

Choose Synchr

oniz

e when z

one heat

ed using a boiler

Choose A

u

to

 when z

one is non-h

ydr

onic heating.

A

vailable when:

No r

ese

t contr

ol on t

he t

ekmarNe

t

®

 sy

st

em.

AD

JUST

AD

JUST

OFF

, 1 t

o

 1

6

Installer

AIR GR

OUP

Select if t

his t

hermostat should be an air gr

oup member

Select of

f if t

he t

hermso

tat is no

t an air gr

oup member

Select 1 t

hough 1

6

 t

o

 select t

he air gr

oup number

.

A

vailable when:

The t

hermostat is connect

ed t

o

 o

ther t

hermostats

 

using t

ekmarNe

t

®

.

On or Of

f

Def

ault = On

Installer

RO

O

M

 S

E

N

S

O

R

Select whe

ther t

he built-in air t

e

mperatur

e sensor is 

on or of

f. 

A

vaila

b

le when

:

A

 floor

 sensor

 or

 room

 sensor

 is

 installe

d

 on

 the

 

auxiliar

y sens

or in

p

u

t.

S

e

tt

ings (

6

 of 7

)

 Continued on ne

xt page.

Содержание D528

Страница 1: ...ating Cycle tN2 Communication compatible Room temperature limiting Requires 2 Wires Pulse Width Modulation CSA C US Approved for use in USA and Canada Outdoor Temperature Display Air Group Member Back...

Страница 2: ...ng the Thermostat Wiring 5 Mounting the Thermostat 5 Cleaning the Thermostat 6 Switch Settings 6 User Interface 7 Display 7 Button Operation 7 Symbols Description 7 Settings 8 14 Sequence of Operation...

Страница 3: ...f wire is 1000 feet 300 m Strip wire to 3 8 10 mm for all terminal connections Use standard 18 AWG wire for the tN2 connections Installation Location Removing The Thermostat Base Push tab 1 Remove the...

Страница 4: ...mmunication are provided to the thermostat by connecting the tN2 terminals on the thermostat to the tN2 terminals on a tN2 Wiring Center House Control Zone Manager or Expansion Module tN2 terminals ar...

Страница 5: ...g Center or Zone Manager If the thermostat display remains permanently on there may be a fault with the previously tried zone on the House Control Wiring Center or Zone Manager If the thermostat displ...

Страница 6: ...setback schedule 2 ON SCENE The thermostat responds to changes in the scene system wide manual overrides Requires the installation of a User Switch 479 to use this feature OFF OFF The thermostat does...

Страница 7: ...GROUP The air group is cooling Heating can start once the cooling is finished LOCK Locked to User access level CLOCK Operating on a programmable schedule tekmarNet Communication is present WARNING SYM...

Страница 8: ...ler SET ROOM HEAT AWAY Set the room heating temperature while in the Away scene Continued on next page Press and hold down both the and buttons for 2 seconds to change from one step to the next Releas...

Страница 9: ...ng in the Adjust menu is set to Off 40 to 122 F 4 5 to 50 0 C Default 65 F 18 5 C Installer User SET FLOOR HEAT Set the floor heating temperature while in the event Available when A slab sensor is ins...

Страница 10: ...rge number with Software Version upper right corner and the thermostat address 40 to 95 F 4 5 to 35 0 C Default 85 F 29 5 C Installer MAXIMUM SET ROOM HEAT Set the maximum room heating limit while in...

Страница 11: ...n AND A slab sensor is installed on the auxiliary sensor input AND Sensor setting in the Adjust menu is set to Floor Off 40 to 122 F Off 4 5 to 50 0 C Default Off Installer User SET FLOOR MINIMUM Set...

Страница 12: ...liary sensor input AND Sensor setting in the Adjust menu is set to Floor 1 2 3 4 Default 1 Installer SCHEDULE Thermostat can follow schedule master 1 2 3 or 4 Available when Switch setting 1 is set to...

Страница 13: ...e tekmarNet system Choose Synchronize when zone heated using a boiler Choose Auto when zone is non hydronic heating Available when No reset control on the tekmarNet system ADJUST ADJUST OFF 1 to 16 In...

Страница 14: ...t control mixing Installer tekmarNet ADDRESS The address is shown in the large number field Auto is shown in the upper number field when using automatic addressing Press the or the button to manually...

Страница 15: ...the thermostat is heating The heat can cycle on and off within 1 5 F 1 C of the Set Room Heat temperature Freeze Protection The thermostat operates the heat whenever the room or floor temperature fall...

Страница 16: ...r the group This thermostat can be set to be a member of the air group When operating as an air group the air temperature readings of all the air group member thermostats are communicated to the air g...

Страница 17: ...e Display Room Temperature Setting 1 or or Follows programmable schedule or operates at the occupied temperature 2 Away Away temperature 3 Unoccupied temperature Scenes System Override Section E When...

Страница 18: ...il all settings have been reviewed PORT ERROR Thermostat has been connected to a tN2 Zone already in use by a 2 stage device A 2 stage device requires two tN2 ports to operate This device may be conne...

Страница 19: ...ears automatically once this thermostat is given a new manually set address or if the thermostat is set to automatic addressing ROOM SENSOR SHORT CIRCUIT The built in air temperature sensor has a shor...

Страница 20: ...r sensor fault is corrected FLOOR SENSOR OPEN CIRCUIT The auxiliary floor sensor has an open circuit Check for loose or damaged wires Locate and repair the problem as described in the Data Brochure D0...

Страница 21: ...CIRCUIT The auxiliary room sensor has a short circuit Check for damaged wires Locate and repair the problem as described in the Data Brochure D 076 D077 or D084 Error clears after the auxiliary room...

Страница 22: ...arly so that the room is comfortable at the scheduled time Pressing button does not increase temperature Flashing Max Installer can increase the Maximum Set Room Heat Flashing Floor Max Floor temperat...

Страница 23: ...o 50 C RH max 80 up to 88 F 31 C decreasing linearly to 50 RH at 104 F 40 C Altitude 0 6560 feet 2000 m Installation Category II Pollution Category 2 Power supply Provided by tekmarNet 2 Control 1 3 V...

Страница 24: ...s not cover the cost of the parts or labor to remove or transport the defec tive Product or to reinstall the repaired or replacement Product all such costs and expenses being subject to Purchaser s ag...

Отзывы: