Installation
STEP ONE
GETTING READY
Check the contents of this package. If any of the contents are missing or damaged, please
contact your wholesaler or tekmar sales representative for assistance.
Type 508 Includes: •• One Thermostat 508 • Data Brochure D 508 •
• User Brochure U 508
STEP TWO
REMOVING THE FRONT COVER
Place a screwdriver or similar object into the small slot located in the top of the thermostat.
Push the screwdriver against the plastic tab and pull the top of the front cover so that it pivots
around the bottom edge of the base.
Menu
Item
Remove cover
Push tab
1
2
MODE
Heat
In the heat mode, the Heat
relay is operated to satisfy the temperature
requirement of the zone.
Off
In the OFF mode, the Heat
relay is not operated.
NOTE:
If an air or slab sensor is active in the OFF mode, a freeze protection is enabled
that allows the Heat relay to be operated to keep the zone above 35°F (2°C).
STEP THREE
MOUNTING THE BASE
The thermostat should be installed on an interior wall of the desired zone approximately 5’ (1.5
m) above the floor. Do not mount the thermostat in a location that may be affected by localized
heat sources or cold drafts. It may be necessary to install a draft barrier behind the thermostat to
prevent air from blowing through the wiring hole and affecting the thermostat’s built-in sensor.
Mount the base directly to the wall using two #6
1” screws. The screws are inserted through the
mounting holes and must be securely fastened
to the wall. If possible, at least one of the screws
should enter a wall stud or similar surface.
If the thermostat is to be mounted to a 2” x
4” electrical box, order an Adaptor Plate 007.
This plate mounts to the electrical box and the
thermostat mounts to the plate. Ensure that the
electrical box does not provide cold air to the
thermostat.
#6 1” screws