The new activated carbon must be
carefully filled into the activated
carbon cassette. Gradually fill with
a number of smaller quantities of
activated carbon, spreading it out
evenly and gently pressing down
on it as you do so.
Only use TEKA spare
filters. Otherwise the proper
functioning of the unit is not
guaranteed.
●
The cassette must be filled with
activated carbon up to the height
of the support surface (A) and
levelled off.
●
Place the new top filter fleece mat
over the activated carbon. It may
be necessary to cut the filter fleece
mat to the right size. The size
must correspond to the
dimensions of the cover.
●
Screw the cover back on again.
When you do this, the cover must
press the top filter fleece mat
against the support surface of the
activated carbon cassette all the
way round.
●
Push the filter pack back into the
filter housing. Make sure that the
filter elements are inserted in the
correct order.
●
Elevate the lifting device by turning
the clamping screw so that the
entire filter pack is pressed tightly
against the above housing.
●
Close the service door.
BA_LMD-501_220127_EN
14
27.01.2022