3
USE
1) BURNERS
A diagram is screen-printed above each knob on the front panel. This diagram indicates to
which burner the knob in question corresponds. After having opened the gas mains or gas
bottle tap, light the burners as described below:
−
Manual ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction
until it reaches the full on position (large flame fig. 1), then place a lighted match near the
burner.
−
Electrical ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction
until it reaches the full on position (large flame fig. 1), then depress and release the ignition
button.
−
Automatic electrical ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction
until it reaches the full on position (large flame fig. 1), then depress the knob.
−
Lighting burners equipped with flame failure device
The knobs of burners equipped with flame failure device must be turned in an
anticlockwise direction until they reach the full on position (large flame fig. 1) and come to
a stop. Now depress the knob in question and repeat the previously indicated operations.
Keep the knob depressed for about 10 seconds once the burner has ignited.
Note: You are advise not to try and light a burner if the flame divider (Burner Cap) is
not correctly place.
In the event of the Burner flames being accidentally extinguished, turn off the
burner control and do not attempt to re-ignite the burner for a least 1 minute.
HOW TO USE THE BURNERS
Bear in mind the following indications in order to achieve maximum efficiency with the least
possible gas consumption:
−
Use adequate pans for each burner (consult the following table and fig. 2).
−
When the pan comes to the boil, set the knob to the reduced rate position (small
flame fig. 1).
−
Always place a lid on the pans.
−
Use only pan with a flat bottom and in thick metal.
Burners
Power
ratings
Pan
Ø
in
(cm)
LPG
NG
Ultra
rapid
11.9
MJ/h
15.0
MJ/h
22
÷
24
Rapid
10.8
MJ/h
12.0
MJ/h
20
÷
22
Semirapid
6.3
MJ/h
7.3
MJ/h
16
÷
18
Auxiliary
3.6
MJ/h
4.2
MJ/h
10
÷
14
WARNINGS:
-
Burners with flame failure device may only beignited when the relative knob
has been set to the Full on position (large flame fig. 1).
-
Matches can be used to ignite the burners in a blackout.
-
Never leave the appliance unattended when the burners are being used. Make
sure there are no children in the near vicinity. Particularly make sure that the
pan handles are correctly positioned and keep a chek on foods requiring oil
and grease to cook since these products can easily catch fire.