Always disconnect the appliance from the electricity main before making any
adjustments.
All seals must be replaced by the technician at the end of any adjustments or
regulations.
Our burners do not require primary air adjustment.
a) Data Label
The Data Label is located on the underside of the hotplate. A duplicate Data Label is
supplied to adhere in an accessible area next o the hotplate. This hotplate is suitable for
Natural Gas and Universal LPG; ensure that the available gas supply matches the Data
Label.
b) Before Leaving
Check that there are no gas leaks, but do not use a naked flame to detect gas leaks. Ignite
all burners to ensure correct operation of gas valves, burners, ignition and if fitted, flame
failure valves. Turn gas taps to low flame position and observe stability of the flame. When
satisfied with the hotplate, please instruct the user on the correct method of operation. In
case the appliance fails to operate correctly after all checks have been carried out, refer to
the authorised service provider in your area.
7) TAPS
Our taps are suitable for all the gas types. They are male conical type at one way.
“Reduced rate” adjustment
-
Switch on the burner and turn the relative knob to the “Reduced rate” position (small
flame fig. 1).
-
Remove knob “M” (fig. 15) of the tap, which is simply pressed on to its rod.
-
Insert a small screwdriver “D” into hole “C” (fig. 15) and turn the throttle screw to the
right or left until the burner flame has been adequately regulated to the “Reduced
rate” position.
Check that the flame does not go out when the knob is sharply switched from the “Full on”
to the “Reduced rate” position.
It is understood that only burners operating with Natural gas should be subjected to
the above mentioned adjustments. The screw must be fully locked when the burners
operate with Liquid gas.
FIG. 15