1
150/ 120 mm reduction.
6
Lock screws (M8 x 45).
Fig. 1 (Page 31)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
10 are complied with.
To obtain optimum performance, the external
conduct must not be more than FOUR
METRES long, have no more than two 90°
angles and its diameter must be at least Ø120.
1) Using the support (O) trace and drill the
where the screw-fittings will sit onto the roof (S)
(Ø8 x 45).
2) Screw the support (O) into the roof with the
screw-fittings (S) (Ø8 x 45).
3) Mount the upper chassis (A6) onto the
support (O) using the screws (Q) (M6 x 16).
4) Adjust the decorative part (U), fixing it softly
to the body of the bell using the screws (V)
(M4) provided with the decorative part.
5) Fit the part (B) if the inner tube (not supplied)
is Ø120.
6) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be.
7) Introduce the upper tubecover (A8) into the
lower tubecover (A9).
8) Fit the lower (A9) and upper (A8) tubecover
units onto the lower body (A7) and the
decorative parts (U).
9) Mount the whole lower unit to the upper
section, attaching it to the roof using the
screws (A10) (M4 x 12) at the required height.
10) Connect the upper part of the inner tube
(not supplied) to the exit.
11) Raise the upper tubecover (A8) and attach
it to the upper unit with the screws (G) (M4 x 12
flat head).
12) Adjust the decorative part (U), fixing it
tightly to the body of the bell using the screws
(V) (M4) provided with the decorative part.
When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active charcoal
filters.
The active charcoal filters have an active life of
between three to six months, depending on
the individual conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.
Fig. 1 (Page 31)
1) Using the support (O) trace and drill the
where the screw-fittings will sit onto the roof (S)
(Ø8 x 45).
2) Screw the support (O) into the roof with the
screw-fittings (S) (Ø8 x 45).
3) Mount the diffuser (A5) with the screws (A4)
(M4 x 12) on to the side rectangles of the upper
body (A6).
4) Mount the upper chassis (A6) onto the
support (O) using the screws (Q) (M6 x 16).
5) Adjust the decorative part (U), fixing it softly
to the body of the bell using the screws (V)
(M4) provided with the decorative part.
6) Fit the part (B) if the inner tube (not supplied)
is Ø120.
7) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be.
8) Introduce the upper tubecover (A8) into the
lower tubecover (A9).
9) Fit the lower (A9) and upper (A8) tubecover
units onto the lower body (A7) and the
decorative parts (U).
10) Mount the whole lower unit to the upper
section, attaching it to the roof using the
screws (A10) (M4 x 12) at the required height.
11) Connect the upper part of the inner tube
(not supplied) to the exit.
12) Raise the upper tubecover (A8) and attach
it to the upper unit with the screws (G) (M4 x 12
flat head).
13) Adjust the decorative part (U), fixing it
tightly to the body of the bell using the screws
(V) (M4) provided with the decorative part.
14) Remove the metal filters. Loosen the
screws (without unscrewing them) of the
EASYCLEAN panels (A19), move the panels
aside carefully and take them off.
15) Put the filters into the lateral draught
section of the motor making the holes in the
filters match up (A11) with the pivots (A12) of
the motor carcass.
16) Mount the EASYCLEAN panel again (A19).
Fit the metal filters.
Active charcoal filters (Optional)