2. Place wiring connections inside of fixture
and mounting plate and engage fixture with
mounting plate. Tighten four (4) 1/4-20 set
screws with 1/8” Allen wrench to secure. Make
sure the fixture is completely seated.
WIRING DIAGRAM
Phase 2 - Fixture Installation
1. Make connections from primary branch circuit
to driver primary leads using watertight wire
connectors (By Others). Connect incoming
dimming controls to driver side dimming
controls. Connect green fixture ground wire to
green primary ground wire. Secondary side is
factory wired.
See wiring diagram.
TOWER BOLLARD™ (TWB)
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
DATE
12-18-17
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2572-00
2. Remove mounting plate assembly from the
fixture base by loosening four (4) 1/4-20 x
1/2” set screws with 1/8” Allen wrench.
Phase 1 - Install Mounting Plate
4.
Seal as per NEC with waterproof silicone sealant
(By Others).
1. Remove 1/4-20 nuts from installed #36 anchor
kit with adjustable crescent wrench.
5.
Pull primary branch circuit wiring necessary for
installation (By Others). Pull incoming dimming
controls for installation (By Others).
3. Attach mounting plate to anchor bolts with
the 1/4-20 nuts and lock washers provided
with the #36 Anchor kit using adjustable
crescent wrench.
LINE
Red
FIXTURE
COM
Hydrolock
Plate
Black
GROUND
Driver
White
Black
Green
DIM +
DIM -
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
HP2RM
HP2 TR
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
PM3
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
Quick
Connect
Driver
FIXTURE
DIM +
DIM -
PM3D
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
LINE
Red
FIXTURE
COM
Remote
Driver
Black
DIM +
DIM -
MA/AP
GROUND
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
DIM +
DIM -
PM3DRM
Fixture
Fixture
Remote
Driver
Fixture
Fixture