tefen MixRite 2502 Скачать руководство пользователя страница 6

6

 - -

Adjusting the MixRite

Every stroke of the MixRite moves a predetermined volume of water with a
predetermined volume of liquid additive. To adjust the volume of the liquid
additive:
1.

 

2.

 

Preset the amount of additives according to the Percentage to Water
Scale that is found on the proportioner.

 

Turn  the  Proportioning Adjuster clock-wise to increase the amount
of additives.

 

Turn the Proportioning Adjuster counter clock-wise to decrease the
amount of additives.

3.

 

Turn the  Proportioning Adjuster slightly, until the U-latch holes of the
Proportioning Lock Nut align with the notches in the Proportioner.

4.

 

Push the U-latch into the U-latch holes of Proportioning Lock Nut until
it is firmly in place.

Adjusting the MixRite

The Air-Bleed  Valve

For proper operation, the MixRite should be free of air. Use the air-relief
valve on the cap of the MixRite  to release trapped air. After initial operation
of the MixRite, apply pressure to the cap (the air release valve) for several
seconds to open valve that allows trapped air to escape. This air release is
accompanied by a slight loss of water. Release the pressure on the cap to
close the valve.

U-latch

To increase

To decrease

Air is released with a
small amount of water

Press to release air

Содержание MixRite 2502

Страница 1: ...r rs s s M M Ma a an n nu u ua a al l l TEFEN Manufacture Marketing Plastic Products 1990 LTD Kibbutz Nahsholim D N Hof Carmel 30815 Israel Phone 972 4 6395550 Fax 972 4 6390813 http www tefenplastic...

Страница 2: ...From 0 2 to 6 Bar From 2 9 to 85 PSI Range of Rate of Additive between 0 2 and 2 Maximum suction hight 3 meter Operation MixRite is powered by water flow with minimal loss of pressure The water engin...

Страница 3: ...ect to the pump 4 Attach the pump to the recorder connectors 5 Position the liquid additive container 1 1 5 meter beneath the pump 6 Check to ensure that the suction pipe is not bent or folded 7 Posit...

Страница 4: ...and a third valve on the direct line 2 Install a 50 75 mesh 250 300 micron filter between the valve and the pump intake 3 Install recorder connectors to each of the pipes that connect to the pump 4 At...

Страница 5: ...itioned 1 1 5 meters above the liquid additives container 2 Screw the MixRite bracket onto a wall or any stable vertical base 3 Press the MixRite onto the bracket The nipples on the MixRite must click...

Страница 6: ...latch holes of the Proportioning Lock Nut align with the notches in the Proportioner 4 Push the U latch into the U latch holes of Proportioning Lock Nut until it is firmly in place Adjusting the MixRi...

Страница 7: ...xRite does not Dismantle the suction pump and Change the draw check the suction seal for damage suction seal The MixRite Check if there is liquid in the Add liquid to makes scratching proportioning co...

Страница 8: ...8 Accessories...

Отзывы: