tefen MixRite 2502 Скачать руководство пользователя страница 4

4

 - -

Installing the MixRite On a Bypass line (off line)

Where water is supplied at a higher flow rate, than the working flow rate of

MixRite must be installed on bypass line. The bypass provides the
possibility to close the operation of the pump while water continues to flow
through the line.

1.

 

Install valves to the water line on each side of the pump and a third
valve on the direct line.

2.

 

Install a 50-75 mesh (250-300 micron) filter between the valve and the
pump intake.

3.

 

Install recorder connectors to each of the pipes that connect to the
pump.

4.

 

Attach the pump to the recorder connectors.

5.

 

Position the liquid additive container 1-1.5 meter beneath the pump.

6.

 

Check to ensure that the suction pipe is not bent or folded.

7.

 

Position the drawing pipe into the additive container. Ensure that the

bottom.

         Intake

Installation of MixRite on By Pass (off line)

Valve

Additive container

Valve

Filter

Valve

Содержание MixRite 2502

Страница 1: ...r rs s s M M Ma a an n nu u ua a al l l TEFEN Manufacture Marketing Plastic Products 1990 LTD Kibbutz Nahsholim D N Hof Carmel 30815 Israel Phone 972 4 6395550 Fax 972 4 6390813 http www tefenplastic...

Страница 2: ...From 0 2 to 6 Bar From 2 9 to 85 PSI Range of Rate of Additive between 0 2 and 2 Maximum suction hight 3 meter Operation MixRite is powered by water flow with minimal loss of pressure The water engin...

Страница 3: ...ect to the pump 4 Attach the pump to the recorder connectors 5 Position the liquid additive container 1 1 5 meter beneath the pump 6 Check to ensure that the suction pipe is not bent or folded 7 Posit...

Страница 4: ...and a third valve on the direct line 2 Install a 50 75 mesh 250 300 micron filter between the valve and the pump intake 3 Install recorder connectors to each of the pipes that connect to the pump 4 At...

Страница 5: ...itioned 1 1 5 meters above the liquid additives container 2 Screw the MixRite bracket onto a wall or any stable vertical base 3 Press the MixRite onto the bracket The nipples on the MixRite must click...

Страница 6: ...latch holes of the Proportioning Lock Nut align with the notches in the Proportioner 4 Push the U latch into the U latch holes of Proportioning Lock Nut until it is firmly in place Adjusting the MixRi...

Страница 7: ...xRite does not Dismantle the suction pump and Change the draw check the suction seal for damage suction seal The MixRite Check if there is liquid in the Add liquid to makes scratching proportioning co...

Страница 8: ...8 Accessories...