3. Troubleshooting
3.1. The pump is equipped with an error detection feature. When encountering an error, the
top LED blinks red, and an error message is displayed.
3.2. Common Errors and Solutions:
Error
Display
Possible Cause
Solution
No signal
from water
meter
Top LED blinks red, and
Er.1
is displayed.
No water flow
The pump will
reactivate
automatically when
water flow returns.
Water meter cable is
not connected.
Recheck connection
between the water
meter and the pump's
input cable.
Water meter cable
malfunction
Replace water meter
cable.
Mainline
water
overflow
Top LED blinks red, and
Er.2
is displayed.
Flow rate exceeds the
maximum allowed.
The pump will operate
in full capacity, with
inaccurate dosage rate.
Reduce the water
flow rate below the
threshold. Or, reduce
the dosage rate and
keep the same water
flow.
No suction
_
Pump suction failure
Make sure the counter
pressure is below 3 bar
(43 psi).
Suction occurs, but
additive returns to tank.
Check the foot valve at
the end of the suction
tube. Try to wash and
clean it.
Abrasion in
pump tube
_
Tube wear and tear
Replace the pump tube
with 3 simple steps:
• Unfasten the 2
screws holding the
clear cover.
• Replace the tube and
attach fittings.
• Fasten the screws.
Pump does
not work.
Display and LED are on.
Pump is on
Off
mode
– water flow without
additive injection.
Change
Off
to one of
the dosage rates.
Display is on,
Prime
is working.
Water meter cable is
disconnected.
Reconnect the cable,
and wait 60 seconds.
Check if the top LED
blinks green.