H1
AUX output configuration: 0=no function associated with the
output, 1=alarm output: norm. Energised, 2=AUX output
related to Dig. in.A4 = 6/7/8 Dig. In. OPEN = AUX de-
energised, Dig. in. CLOSED = AUX ene LED “AUX”
display”
-
0
0
H2
Enable keypad (0=keypad disabled,1=keypad
enabled,2=keypad enabled except for ON/OFF)
-
2
2
H4
Disable buzzer (0=buzzer enable,1=buzzer disable)
-
0
0
H5
ID code (read-only)
-
-1
0
EZY
Rapid parameter set selection
-
4
4
5.1.1
Common Defrost
▪
If the multiplexing cabinet is operated as slave module depending on the master module,
parameter A4 must be set as 3 (factory
set). Parameter “A4 = 3” means defrost start
(pulse-pressure) via the signal received from master module. This maintain simultaneous
defrosting in the cabinets on the same multiplexing line.
▪
Connect P3 connector of master cabinet to the P2 connector of slave cabinet to initiate
common defrost (see wiring diagrams).
▪
Master cabinet initiate defrost for both cabinets if required connection is made properly.
▪
If master cabinet terminates defrost regarding to parameters “dt” or “dp”, slave cabinet
also terminates if required connection is made properly.
▪
Slave cabinet terminates defrost if parameter “dt” reaches defrost end temperature
without waiting a signal from master cabinet.
Содержание EXPRESS EX125C
Страница 9: ......
Страница 10: ......
Страница 24: ...6 Wiring Diagrams 6 1 TEFCOLD EXPRESS EX125C OPEN FRONTED ...
Страница 25: ......
Страница 26: ...6 2 TEFCOLD EXPRESS EX187C OPEN FRONTED ...
Страница 27: ......
Страница 28: ...6 3 TEFCOLD EXPRESS EX250C OPEN FRONTED ...
Страница 29: ......
Страница 30: ...6 4 TEFCOLD EXPRESS EX125CD WITH DOOR ...
Страница 31: ......
Страница 32: ...6 5 TEFCOLD EXPRESS EX187CD WITH DOOR ...
Страница 33: ......
Страница 34: ...6 6 TEFCOLD EXPRESS EX250CD WITH DOOR ...
Страница 35: ......
Страница 55: ......