![Teesa PURE LIFE P300 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/teesa/pure-life-p300/pure-life-p300_owners-manual_1073465006.webp)
23.When ozoning the air in closed rooms there should be no people in it. After the generator
work is finished, open the room and after about 30 minutes you can enter it.
24.After the generator work is finished, the room should be ventilated for about 3 hours.
25.After every 180 minutes of operation, wait 10 minutes before starting again. Failure to
comply with this rule may result in device failure.
OPERATION
10
Owner’s manual
11
EN
EN
Owner’s manual
ASSEMBLING / DISASSEMBLING
INTENDED USE
The device can be used for the following purposes:
• Disinfection and ozonation of indoor air: removal of unpleasant odors, bacteria, pathogenic
microorganisms, fungi, allergens, virus mites, mold.
• Disinfection and ozonation of the aquatic environment: drinking water, bathing water, etc.
• Disinfection and ozonation of food, fruit and vegetables.
• Disinfection and ozonation of vehicles: car air conditioning, interior disinfection, removal of
unpleasant odors.
CONNECTING ACCESSORIES
1. To connect the silicone tube to the ozone outlet, insert the end of the tube into the ozone
outlet.
2. To connect the stone diffuser to the silicone tube, insert the end of the diffuser into the
tube.
3. Stone diffusers are intended for ozoning liquids.
1. The device can be used by placing it on a flat surface or mounting it on the wall.
2. The rear of the device has holes for wall mounting, using hooks or mounting screws of the
right size (not included).
• To turn on the device, press the power button (the power LED will light up) and set the timer
to the desired operating time. The generator will not work without setting the timer.
• The timer range is from 1 to 60 minutes.
• When ozoning water, the device should be above the water level.
• To turn off the device, press the power button again (the power LED will go off ).
• If the timer adjustment knob is in a position other than 0 after use, turn it to 0.
• After every 180 minutes of operation, wait 10 minutes before starting again. Failure to
comply with this rule may result in device failure.
CLEANING AND STORAGE
• Prior to cleaning, disconnect the device from power mains.
• Clean the device with a soft, slightly damp cloth.
• Accessories should be washed under running water.
SPECIFICATION
BASIC FEATURES
Analog timer
Mountable on the wall
Universal use
TECHNICAL DATA
Ozone output: 600 mg/h
Timer range: 1-60 mins
Sound power level: 58-65 dB
Power cable lenght: 165 cm
Nominal power: 8 W
Power input: AC 220 V; 50 Hz
PHYSICAL PARAMETERS
Dimensions: 270x190x75 mm
Weight: 0,75 kg
IN SET
2x Silicone tubes
2x Stone diffusers
User’s manual
English
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems) This marking shown on
the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working
life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this
from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household
users should contact either the retailer where they purchased this product, or their local government office, for details of
where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and
check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes
for disposal.
Made in China for LECHPOL ELECTRONICS Sp. z o.o. Sp.k., ul. Garwolińska 1, 08-400 Miętne.