teel 4RK45 Скачать руководство пользователя страница 6

Maintenance (Continued)

8. Reinstall capacitor (Single phase

only). See Figure 6 for electrical
connections to capacitor.

9. Fill motor with clean dielectric oil

(Part No. U197-8A). To allow room
for expansion, oil level with cold
motor should be about 1/4" 
(6-7mm) above top of motor
assembly.

10. Inspect capacitor cover O-Ring;

replace if damaged. If it is not
nicked or scratched, clean and
reinstall.

NOTE: 

It is good practice to replace 

O-Ring each time pump is serviced.

11. Reconnect motor lead wires to

connector. Reference color code
markings. Reinstall capacitor cover.

6

Teel Operating Instructions and Parts Manual

4RK45, 4RK46, 4RK47, 4RK48, 4RK49, 4RK62 and 4RK63

Teel Submersible Effluent and
Sewage/Solids Handling Pumps

®

E

N
G

L

I

S

H

Limited Warranty

DAYTON ONE-YEAR LIMITED WARRANTY.

Teel

®

submersible effluent and sewage/solids handling pump, Models covered in this manual,

are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against defects in workmanship or materials under normal use for
one year after date of purchase. Any part which is determined to be defective in material or workmanship and returned to an authorized
service location, as Dayton designates, shipping costs prepaid, will be, as the exclusive remedy, repaired or replaced at Dayton’s option. For
limited warranty claim procedures, see PROMPT DISPOSITION below. This limited warranty gives purchasers specific legal rights which vary
from jurisdiction to jurisdiction.

LIMITATION OF LIABILITY.

To the extent allowable under applicable law, Dayton’s liability for consequential and incidental damages is

expressly disclaimed. Dayton’s liability in all events is limited to and shall not exceed the purchase price paid.

WARRANTY DISCLAIMER.

Dayton has made a diligent effort to provide product information and illustrate the products in this literature

accurately; however, such information and illustrations are for the sole purpose of identification, and do not express or imply a warranty
that the products are MERCHANTABLE, or FIT FOR A PARTICULAR PURPOSE, or that the products will necessarily conform to the illustrations
or descriptions.

Except as provided below, no warranty or affirmation of fact, expressed or implied, other than as stated in the “LIMITED WARRANTY”
above is made or authorized by Dayton.

PRODUCT SUITABILITY.

Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use of products

for certain purposes, which may vary from those in neighboring areas. While Dayton attempts to assure that its products comply with such
codes, it cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a
product, review the product applications, and all applicable national and local codes and regulations, and be sure that the product,
installation, and use will comply with them.

Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you; (b) also, some jurisdictions do not allow a
limitation on how long an implied warranty lasts, consequently the above limitation may not apply to you; and (c) by law, during the period
of this Limited Warranty, any implied warranties of implied merchantability or fitness for a particular purpose applicable to consumer
products purchased by consumers, may not be excluded or otherwise disclaimed.

PROMPT DISPOSITION.

Dayton will make a good faith effort for prompt correction or other adjustment with respect to any product which

proves to be defective within limited warranty. For any product believed to be defective within limited warranty, first write or call dealer
from whom the product was purchased. Dealer will give additional directions. If unable to resolve satisfactorily, write to Dayton at address
below, giving dealer’s name, address, date, and number of dealer’s invoice, and describing the nature of the defect. Title and risk of loss
pass to buyer on delivery to common carrier. If product was damaged in transit to you, file claim with carrier.

Manufactured for Dayton Electric Mfg. Co., 5959 W. Howard St., Niles, Illinois 60714  U.S.A.

Leads From

Stator

White

Red

Black

Green

Black

Capacitor

Figure 6 – Electrical Connections to
Capacitor

Содержание 4RK45

Страница 1: ...t iron 201 2 167 8 20 122 4RK48 Cast iron Cast iron Cast iron Cast iron 201 2 167 8 20 121 4RK49 Cast iron Cast iron Cast iron Cast iron 201 2 167 8 20 122 4RK62 Cast iron Cast iron Cast iron Cast iro...

Страница 2: ...wired to interrupt power to all three incoming phases Three phase pumps are intended for permanent connection only Provide strain relief at control box for power supply cord connection to box All cont...

Страница 3: ...tions on Page 1 OVERLOADS SINGLE PHASE In single phase units an automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down prote...

Страница 4: ...mbling pump The pump motor housing contains a special lubricating oil Keep oil clean and free of water at all times NOTE Whenever motor cover is being removed for service remove oil and replace with n...

Страница 5: ...et head screws NOTE It is good practice to replace O Ring each time pump is serviced 4 Turn assembly upside down and slide new rotating member of seal onto shaft Apply soap to rubber ring to aid in sl...

Страница 6: ...arily conform to the illustrations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or author...

Страница 7: ...is not high enough 2 Check that fluid level is high enough to activate to activate switch or controller switch or controller 3 Plugged vent hole in discharge pipe 3 Check to be sure that the 3 16 vent...

Страница 8: ...62SS U30 62SS U30 62SS U30 62SS 4 14 1 4 20 x 1 Capscrew U30 475SS U30 475SS U30 475SS U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 U30 941 U30 941 U30 941 4 16 3 16 x 3 4 Impeller ke...

Страница 9: ...U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 4 16 Shaft seal U9 394SS U9 394SS 1 17 Retaining washer PW43 5SS PW43 5SS 1 18 Retaining ring U9 353SS U9 353SS 1 19 Lip seal U9 417 U9 41...

Отзывы: