SmartPad II
Software Version 4.02
Chapter 4 - Waypoint Navigation
4-37
Nav 2 Point Real-Time Scenarios
Editing or Deleting a Sample Point
This section will describe how the operator may edit or delete an existing sample point. The operator should have the
ability to edit or delete any sample point that is present in the view page. Due to the lack of a pointing device on the
current SmartPad, we will require the operator to drive towards the point they wish to edit or delete. We will use the
Alarm Range value to determine when to place the Edit Sample and Delete Sample buttons in the button bar. This fea-
ture will work regardless of the Alarm menu item status. The operator may want to turn the alarm off but still be able
to edit or delete Sample points.
Figure 4 -47 shows the vehicle driving to with in the Alarm Range of a sample point. The left side of this figure shows
the button bar as it would appear if no points were with in range. Once a sample point is with in range, the Delete
Sample point and Edit Sample point buttons are placed in the button bar, right side Figure 4 -47. The Sample Point
with in the Alarm range should also have its point number displayed next to the point in the view page. The informa-
tion bar located at the bottom the of the view page will also alternate between the quick help message of the high-
lighted button and the sample point information. If there are more than one sample point with in the Alarm Range, the
closest point information will be displayed and will be subject to either editing or deleting.
Editing a Sample Point
Once the operator has the Sample point they choose to edit with in range, they arrow down and highlight the Edit
Sample button and press
. This will bring up the Sample Name dialog, Figure 4 -48, with the current point sample
name in the edit box. The operator can now change the sample name and then press to accept. Once
is pressed the
Sample Number dialog will appear, Figure 4 -49, again the operator can edit the current number and the press
to
accept. If either the Sample Number or Sample name has been set to OFF in the Data Setup menu, then that dialog
will no be presented to the operator. If both Sample Name and Sample Number are set to off, the Edit Sample point
button will not be placed in the button bar when a sample point falls with in the Alarm Range.
Figure 4-47: Driving to with in the Alarm Range
Содержание SmartPad II
Страница 1: ...SWATH XL GUIDELINE SMARTPAD II USER GUIDE Software Version 4 02 98 05067 R0 MID TECH...
Страница 8: ...1 8 Table of Contents SmartPad II Software Version 4 02...
Страница 22: ...1 14 Chapter 1 Introduction Chapter 1 Notes SmartPad II Software Version 4 02 Chapter 1 Notes...
Страница 54: ...2 32 Chapter 2 Software Overview Chapter 2 Notes Fieldware for Smartpad II Software Version 4 02...
Страница 130: ...3 76 Chapter 3 Real Time Guidance Chapter 3 Notes SmartPad II Software Version 4 02 Chapter 3 Notes...
Страница 172: ...4 42 Chapter 4 Waypoint Navigation Chapter 4 Notes SmartPad II Software Version 4 02 Chapter 4 Notes...
Страница 197: ...Fieldware for Smartpad II Software Version 4 02 Chapter 5 Field Mapping 5 25 Chapter 5 Notes Chapter 5 Notes...
Страница 198: ...5 26 Chapter 5 Field Mapping Chapter 5 Notes Fieldware for Smartpad II Software Version 4 02...