CHAPTER 2 – INITIAL START-UP & CALIBRATIONS
This section will explain basic setup of the values required for first-time setup of a DynaJet Flex system. When these settings are
completed, initial operation and fine-tuning should be possible.
WARNING! With each nozzle change or when nozzles are replaced, a system calibration (steps 4-7) must be completed before
attempted operation. Failure to properly configure and calibrate the system will result in sub-standard performance. Once
complete, operation may proceed.
NO. 1 BASIC SCREEN USE
Upon startup, the system will cycle the following screens.
X
Initialisation Screen – During power-up, the Initialisation
screen is displayed for five (5) seconds, or until all drivers
are scanned.
X
Work Screen – Once initialisation is complete, the Work
screen will appear.
Prior to operation, all settings and configurations must be
established. Please contact a dealer or TeeJet Customer service
representative with questions about system operations. TeeJet
Technologies is not responsible for misuse or incorrect operation
of the system. Settings are automatically saved when selected.
Select functions may not be visible due to OEM settings, available
equipment or sensors.
Menu Options
To access menu options from the work screen, press the centre of
the screen.
Favourites – used to access favourite spray nozzles.
This function automatically stores the most recent five
(5) nozzles chosen.
Setup – used to access settings. This will enter the
configuration menu.
Nozzle Selection – used to select the spray nozzle style
and capacity. Once chosen here, the spray nozzle style
and capacity is automatically added to the favourites
list.
Diagnostics – used to diagnose and observe operating
issues of the system and booms.
Figure 2-1: Options Menu